Plan Number: T11PI00004
Parcel: Unknown

Address:
550 N 5TH AV

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T11PI00004
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2011 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved No objection pertaining to Street Maintenance.
03/14/2011 GARY WITTWER DOT LANDSCAPE REVIEW Denied 1. Please add Standard Notes for planting in ROW. If you do not have these - please e-mail me and request.
2. You will need an easement for irrigation lines under public roadway.
03/28/2011 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Denied
03/28/2011 RICHARD LEIGH DOT ENGINEERING REVIEW Denied 03/25/2011


SUBJECT: THE DISTRICT I-2011-005, T11PI00004, 1st Rev.

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Include the plan number "I-2010-005" in title block of each sheet.

2. Include Development Services Department PIA activity number "T11PI0004" on cover sheet.

3. Provide recordation information, Book & Page, of associated development on cover sheet.

4. Revise title block so that the title block information is identical on all sheets except for sheet number. Extraneous labeling such as details of sheet or the street name may be labeled above title block.

5. Submit approved development plan with next submittal. Based on approved development plan additional comments may be generated.

6. Submit approved drainage report with next submittal.

7. Show all symbols and lines in the legend per PC/COT S.D. 100.

8. Clearly label all proposed structures within the public rights-of way.

9. Delineate and dimension all existing and proposed easements and label with purpose and recordation information in plan view.

10. Provide a right-of-way easement for where the roadway encroaches onto private property.

11. Clearly show existing curb and other existing roadway infrastructure, per COT standards.

12. Show all proposed improvements within the public rights-of-way along 6th Street.

13. Provide roadway centerline and curve data.

14. Clearly show property/rights-of-way limits. Property boundaries should reflect proposed right-of-way dedications.

15. Provide complete details for any proposed hardscape and landscaping within the public rights-of-way.

16. There appear to be discrepancies with spot elevations and labeled pavement slopes, verify and correct.

17. Provide a profile view for the proposed roadways, per COT drafting standard.

18. Indicate the placement of survey monuments at roadway intersection.

19. Show curb returns radii.

20. The proposed raised open drainage channel along 5th Street poses a tripping hazard. Additionally, parked vehicles may obstruct storm water flows. A valley gutter across Herbert Avenue directing flows along new curb alignment should be considered.

21. Provide sidewalk and curb access ramps for pedestrian travel across 5th Street.

22. Have easements been secured for the proposed monuments "Neighborhood Lava Stone Pier" along 5th Street?

23. Verify that the cross slopes for pedestrian crosswalk areas do not exceed 2% and indicate this on plan view.

24. Sheet 10, Detail I & J: Indicate pavement structural section.

25. Sheet 10, Detail F & G: cross section shows the footer of wall on private property. Has an easement been obtained from the property owners? Who will be responsible for the maintenance of these walls?

26. Provide details of the proposed screen wall.

Refer to redline plans for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov
03/28/2011 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
03/28/2011 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Denied
03/28/2011 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Denied
03/28/2011 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
03/28/2011 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Denied
03/28/2011 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
03/28/2011 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Denied
03/28/2011 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Denied
04/07/2011 JOSE ORTIZ DOT TRAFFIC REVIEW Denied April 7, 2011
ACTIVITY NUMBER: T11PI00004
PROJECT NAME: The District
PROJECT ADDRESS: 550 N 5th Ave
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal.

The following items must be revised or added to the plan. See redlines on the submitted drawings and address the redline comments. During the next submittal please re-submit the roll of redlines for back checking purposes.

In previous conversations the site and offsite improvements maybe revised so during the submittals illustrating these revisions additional or different comments may be generated due to the revision to the site.



If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
04/08/2011 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed Please submit Utility Receipts from the following utility companies:

City of Tucson
Transportation Department,
Streets Division

Tucson Water:

Pima County
Wastewater Management

Qwest Communications

Tucson Electric Power

Cox Communications

Southwest Gas Corp.

El Paso Natural Gas*

Kinder Morgan Energy*
04/08/2011 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed Please submit Utility Receipts from the following utility companies: