Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T11PI00003
Parcel: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T11PI00003
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/08/2011 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved No objection pertaining to Street Maitenance.
03/10/2011 JOSE ORTIZ DOT TRAFFIC REVIEW Denied March 10, 2011
ACTIVITY NUMBER: T11PI00003
PROJECT NAME: NWC Harrison/O S T
PROJECT ADDRESS: 1010 S Harrison Rd
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. The following items must be revised or added to the plan. Include a response letter with the next submittal that states how all comments have been addressed.

1. See redlines on the submitted drawings and address the additional redline comments. During the next submittal please re-submit the roll of redlines for back checking purposes.

2. Along Old Spanish Trail ensure that all existing signs that are effected by the off-site improvements and are applicable to the roadway remain in place or relocated to an appropriate location. If damaged or unsuitable for reuse then replace with new sign and/or post.

3. If existing striping widths permit restripe Old Spanish Trail from Speckle Stone Way to Harrison with a 3-lane cross section plus 2 bike lanes. The 3-lane cross section shall consist of one eastbound through lane, one westbound through lane and a continuous two-way left turn lane.

4. Place the PIA and CDRC Case number on the cover sheet.



If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
03/14/2011 GARY WITTWER DOT LANDSCAPE REVIEW Approved
03/21/2011 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Denied
03/21/2011 RICHARD LEIGH DOT ENGINEERING REVIEW Denied March 17, 2011


SUBJECT: NWC HARRISON AND OLD SPANISH TRAIL, I-2011-004, T11PI00003, 1st Rev.

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal.

1. Include the plan number "I-2010-004" in title block of each sheet.

2. Include Development Services Department PIA activity number "T11PI0003" on cover sheet.

3. Submit approved development plan with next submittal.

4. Submit approved drainage report with next submittal.

Refer to redline plans for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov
03/21/2011 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed Plase submit Utility Receipts from the following utility companies:

City of Tucson
Transportation Department,
Streets Division

Tucson Water:

Pima County
Wastewater Management

Qwest Communications

Tucson Electric Power

Cox Communications

Southwest Gas Corp.

El Paso Natural Gas*

Kinder Morgan Energy*
03/21/2011 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
03/21/2011 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed Plase submit Utility Receipts from the following utility companies:

City of Tucson
Transportation Department,
Streets Division

Tucson Water:

Pima County
Wastewater Management

Qwest Communications

Tucson Electric Power

Cox Communications

Southwest Gas Corp.

El Paso Natural Gas*

Kinder Morgan Energy*
03/21/2011 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Denied
03/21/2011 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Denied
03/21/2011 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
03/21/2011 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Denied
03/21/2011 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
03/21/2011 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Denied
03/21/2011 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Denied