Permit Review Detail
Review Status: Active
Review Details: FLOODPLAIN
Permit Number - T11OT01606
Review Name: FLOODPLAIN
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/19/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | August 29, 2014 FLOODPLAIN USE PERMIT # T11OT01606 PROJECT ADDRESS: 211 E Navajo Rd APPLICANT'S NAME: Robert Logan The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C1688/99L, specifically described as: Parcel 106-04-2460; GARDEN HOMES LOT 8 BLK 12 For the purpose of constructing 2 separate buildings for a new Single Family Residence in a mapped 100-year floodplain per FEMA Special Flood Hazard Area Zone AE. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the owner. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 11 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application and the site plan prepared for this project. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) Provide the following notes on the proposed site plan for Engineering approval: a. This project is affected by the City of Tucson Floodplain Regulations. b. Finished floor elevation certificates are required for this project. c. Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan. 4) The proposed buildings are located within a mapped 100-year floodplain, therefore it is required to place the lowest finished floor elevation and any service equipment elevation 1-foot above the calculated Base Flood Elevation. Verify on the site plan that the minimum finish floor elevation of 2343.0 feet NAVD88 is labeled for each structure. 5) For purposes of this permit the following flood elevations shall be used: Base Flood Elevation (BFE) = 2342 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2343 feet NAVD 1988 The lowest finish floor elevation and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 6) Floodplain Approval of elevation certificates, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificates must include the identity and elevation of the lowest service equipment/machinery servicing the single-family residence as well as the identity and location of all other equipment/machinery servicing the single-family residence. 7) All work shall conform to the approved details and site plan per the FUP, which are made part of this permit. 8) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T11OT01606 FOR INFORMATION PLEASE CALL 791-5550." 9) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 10) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 11) See the associated activity T14CM05598. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson Planning & Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 08 Day: 29 Year: 2015 APPLICANT: Robert Logan ADDRESS: 3421 N Calle De Beso PHONE: (520) 360-7095 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/09/2014 | CPIERCE1 | APPROVAL SHELF | RECEIVED |