Permit Number: T11OT01527
Parcel: 11615088L

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11OT01527
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/07/2011 ELIZABETH LEIBOLD ENGINEERING REVIEW Approved FLOODPLAIN USE PERMIT : T11OT01527 (bldg permit: T11CM02433)
PROJECT ADDRESS: 1601 W St Marys Road, Tucson AZ 85745
PROPERTY OWNER: St Mary's Hospital & Health Center
APPLICANT: Metro Permit Express for Carondelet Health Network
This project lies in a FEMA Zone A (map number 04019C 2276L). The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:
Parcel 116-15-088L, 1601 W St Marys Road, PTN FRAC LOTS 1 2 10 11 & 12 N2 SE4 LYG W OF SILVERBELL & S OF ST MARY'S & N OF ANKLAM 17.17 AC, in a portion of Township 14 South, Range 13 East, Section 10,
for the purpose of canopy improvements located on the east side of the main hospital structure.
In reviewing this Floodplain Use Permit application for improvements to an existing floodprone structure, it has been concluded that the cumulative value of improvements to this structure, as supported by documentation provided by the applicant, is less than 50% of the current value of the existing structure.
The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.
This floodplain use permit is issued with the following 12 conditions:
1) This project is located in Zone A as shown on upcoming FIRM panel 2276L. The building is impacted by the FEMA floodplain, although a CLOMR has been issued, the project has shown floodplain compliance by providing paperwork showing that this canopy improvement is not substantial improvement for the structure.
2) To assess cumulative substantial improvement, cost estimate ($1,374,492.00) was provided showing that the improvements are less than 50 % (estimate for T11OT01584 is 2%) indicating a cumulative total percentage of 28.1% of the assessed value of the structure excluding land value, as shown on Pima County Assessor Property data provided by the consultant. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and any future improvements will be added to it.
Estimated cost of improvement (construction) = $1,374,492.00
Assessed value (2011) of the existing structure = $68,160,719.00 (main bldg)
Previous cumulative improvements total: $17,808,042.00
Cumulative percentage of improvements to the existing structure:
$19,182,534.00 / $68,160,719.00 = 28.1%
3) This Floodplain Use Permit T11OT01527 is issued concurrently with the associated improvement plans/permit T11CM02433. Copies of these documents shall be kept in a readily accessible location on site at all times.
4) All work shall conform to the attached plans which are made part of this permit. The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents. This permit is specific to the improvements for the building specified as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.
5) Within 5 (five) days of issuance of this permit, and continuing through to the completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T11OT01527. For information please call 791-5550."
6) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by greater than 50 percent of the existing structure's value.
7) All future improvements will be cumulative in percentage, to include this project. When the cumulative improvements equal or exceed 50% of the current value of the structure; no other improvements will be permitted unless the entire structure is brought into compliance with the City of Tucson Floodplain and Erosion Hazard Area Regulations (Chapter 26, Tucson Code). If the project is determined to be a substantial improvement, and, if it is determined that the lowest flood elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for flood regulation compliance will be required and shall conform to current City of Tucson floodplain development requirements in effect on the date of authorization by the Planning & Development Services Department.
8) For future improvements to this structure, a qualified appraisal shall be provided to Planning & Development Services Department - Engineering Division. The appraisal shall serve as documentation, as required, demonstrating that the value of the future improvements to this structure is less than 50% of the current value of the total appraised/assessed value of the existing structure, not including the land. An application / processing / submittal fee (and if applicable, any review fees) must accompany each future request for work to be authorized for this building structure. Engineering study review fees may be imposed based upon the fee schedule in the current floodplain ordinance. It shall be the responsibility of the owner to supply the following for all work to be authorized for future improvements:
" An 8-1/2" x 11" map locating improvement on this parcel
" Description of improvement
" Provide permit activity number(s)
" Title of improvement
" Type of assessment used for valuation
" Cumulative value of the building structure
" Value of proposed improvement in U. S. Dollars
" A calculated percent improvement
9) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. The existing drainage patterns at the property lines shall not be obstructed nor changed.
10) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the structure and or site development.
11) This permit expires October 22, 2013. If extension is not requested prior to expiration date, renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year, at the sole discretion of the City Engineer or designated representatives.
12) See the associated permit T11CM02433.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.
PROJECT ADDRESS: 1601 W St. Mary's Road, Tucson AZ 85745
PHONE: (520) 990-6866
PROPERTY OWNER: St Mary's Hospital & Health Center
APPLICANT: Metro Permit Express for Swaim Assoc. for Carondelet Health Network
(EXPIRATION DATE) Month: 10 Day: 22 Year: 2013