Permit Number: T11OT00768
Parcel: 11615087D

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - FLOODPLAIN

Permit Number - T11OT00768
Review Name: PLANS OK TO SUBMIT - FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/20/2011 PAUL MACHADO ENGINEERING REVIEW Approved April 20, 2011 (No special Inspection Required).

FLOODPLAIN USE PERMIT NO. T11OT0768
ADDRESS: 1701 W. St. Marys Rd, Ste. 111, Tucson, Arizona, 85745
PROPERTY OWNER'S NAME: Health Care Realty

The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as (legal description):

A Portion of the East 311.91' of the West 580' S568.11' of the North 590' Lot 2 Lyg Adjacent to and South of South 3.62 AC, all in Section 14, T-14-S, R-13-E, in the recorders office of Pima County, Arizona, for the purpose of constructing improvements to an existing residential building.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit. (Or refer to Chapter 26 page 35)

1. All work shall conform to the attached plans (Drainage Report and all improvement plans) which are made part of this permit.

2. The construction cost of the improvements shall not exceed 50% of the total appraised/assessed value of the existing structure, not including the land.

Estimated cost of improvement (construction) = $39,758.0
Assessed value (2011) of the existing improvements
(i.e. structure), excluding the value of the land = $2,210,065.0

The percentage of improvements to the existing residence:
$39,758.0/ $2,210,065.0= 0.0179 (100) = 1.8%

3. The existing drainage patterns at the property lines shall not be obstructed or changed.

4. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T11OT00768. For information please call 791-5550."

5. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

6. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

7. Any patio walls to be constructed will require a separate Floodplain Use Permit.



This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section.

(EXPIRATION DATE) Month: 04 Day: 20 Year: 2012

APPLICANT NAME: Rayann Coffman, STG Design
ADDRESS: 1820 E. River Rd., Ste. 230
CITY: Tucson, Arizona, 85718
PHONE NO.: (520) 577-9511


___________________________ _____________
APPLICANT'S SIGNATURE: DATE:

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.