Permit Number: T11OT00350
Parcel: 111073700

Address:
3422 E GLENN ST

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T11OT00350
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/07/2011 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee, up to five (5) feet of the required ten (10) foot width be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets. It appears that some of the required landscaping is not on site. Obtain permission for use of ROW.

2. A 5' continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I

3. A 5' wall is required to screen adjacent residential properties from the entire vehicle use area per LUC Table 3.7.2-I.

4. Within a vehicular use area, every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1. Verify that the site meets requirement.
04/08/2011 ANDREW CONNOR NPPO REVIEW Approved
04/21/2011 DAVID RIVERA ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/26/2011 DELMA ROBEY OUT TO CUSTOMER Completed
04/26/2011 SUE REEVES REJECT SHELF Completed