Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T11CM03896
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/06/2012 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/21/2011 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 12/21/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 12/22/2011 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/22/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Complete detail 2/M02.02 to show the proposed changes to the mechanical piping. |
| 12/22/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 12/22/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/22/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide information to show that the hub drain complies with Sections 411.1 and 804.1, UPC 2006. Detail 1/P00.02 calls for the hub drain to be located in an exposed position but the plumbing plan shows the hub drain located inside a cabinet. 2. Provide information to show how the proposed water heater platform is to be connected to the building structure. Reference: Section 314.5, UPC 2006. 3. Verify that the floor sink shown in detail 3/P01.02 is located so it is readily accessible and visible for cleaning and inspection. Reference: section 804.1, UPC 2006. 4. Appliances (e.g. coffee makers, ice machines, etc) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps conforming to Table 6-3, UPC 2006 require backflow prevention. Specify the type of backflow prevention device required for each water connection. Reference: Sections 602.3, 603.0, and Table 6-2, UPC 2006. |
| 12/22/2011 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 12/22/2011 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 12/23/2011 | MARTIN BROWN | FIRE | REVIEW | Approved |