Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T11CM03838
Parcel: 110120960

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T11CM03838
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2012 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed Impact Fees paid with building shell permit
01/04/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Secondary condensate drains shall discharge to a conspicuous point of disposal and shall not damage any building component. Terminating a secondary condensate drain over the floor of a janitor's closet does not comply with either of those two requirements. Reference: Section 307.2.3 IMC 2006.
2. Clarify the last four lines of the remarks section of the fan coil schedule on sheet M4.2. Reference: Section 106.3.1, IMC 2006.
01/04/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide plumbing plans for the new work, including water isometrics and waste and vent isometrics. Provide sufficient information to show how the installation of the new plumbing fixtures and piping will relate to the water supply and sanitary waste systems being installed as part of the building shell activity. Show that the new installations will not cause the existing piping to become overloaded. Reference: Sections 101.5.1 and 103.2.3, UPC 2006.
2. Show how the temperature of the hot water supply to the public lavatories is controlled. Reference: Section 413.1, UPC 2006 and Section 504.3, IECC 2006.
3. Show how the service water heating equipment is capable of allowing a control set point of 90 degrees Fahrenheit to non-residential occupancies. Reference: Section 504.3, IECC 2006.
01/04/2012 ROBERT SHERRY WATER REVIEW Approved
01/04/2012 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied 1. SHEETS A2.2 AND A2.3: Corridors 16216 plus 16100B and 16100B plus 16234 are non-compliant with the 2006 IBC, Section 1017.3-Exception 2, that states a 50'-0" maximum length for sprinklered dead end corridors.
2. For all "AREAS ON HOLD PENDING EQUIPMENT SELECTION":
a. Please provide a summary of deferred submittals to the building official for the purpose of addition plan review fees.
b. Please provide structural calculations for any and all suspended equipment.
3. At detail 4/A10.1, provide diagonal bracing to the structural above as shown on detail 2/A10.1.
4. Please provide a large scale plan for all drinking fountains showing accessible clearances. This does not include the set shown in Lobby 16002.
5. Please show vertical dimensions for the drinking foundion shown on detail 115/A7.6.
END OF REVIEW
01/13/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Denied T11CM03838
5301 E Grant Rd
TMC, West Wing

Electrical Plans denied for following:
1. Indicate on Sheet E0.1, Electrical Installation to Comply With 2005 NEC, 517,Health Care Facilities.
Indicate type of wiring methods to be used.
2. Provide 2006 IECC Lighting Budget Calculations, per C of Tuc Submittal Requirements.
3. Sheet E2.1, there are no circuits listed for lighting in rooms 16324 thur 16327. There are no circuits shown for hall and corridor fixtures. Please mark on this sheet even if shown on other sheets.
4. Sheet E2.2, some lighting circuits are no shown for the fixtures this sheet. Review and verify all lighting is circuited.
5. Sheet E2.3, not all lighting circuited.
6. Sheet E2.4, not all lighting circuited.
7. Sheet E2.5, not all lighting circuited.
8. This set of plans shall provide panel locations used with this job rather than having to refer to another set for locations.
9. Sheet E7.1, Pnl S1TOI PC circuits 31 and 33 are used on power plan not in panel schedule.
Pnl SITOI PCBA, circuit 29,31,38,40 and 42 used in power plan marked as spares in schedule.
Pnl SITOI PC circuits 32 and 33 on power plan not in schedules.
Pnl SITOI PCBC circuits 1,3,5,7 and 9 used in power plans not in schedule.
Pnl SITOI PA circuits 13,15,17,19,21,23,25,27,29,31,33,and 35 not found on plans.
Pnl SITOI PD circuits 1,3,5,7,9,11,13,15,17,19,21,and 23 not found on plans.
Provide a panel schedule for Pnl SITOI LA and SITOI BC.
9. How are load calculations on service equipment going to be counted and added to keep an on going tabulation ? There is no total count for load on service equipment on this set of plans,

Indicate how each item was reviewed and how each dealt with.

Ray T Majuta
PDSD,C of Tuc
Elect Plan Review
1/15/12
Ray.majuta@tucsonaz.gov
01/19/2012 GERRY KOZIOL WWM REVIEW Approved
01/23/2012 TERRY STEVENS ZONING REVIEW Approved
12/21/2011 RONALD BROWN ADA REVIEW Passed
12/22/2011 MARTIN BROWN FIRE REVIEW Approved