Permit Number: T11CM03793
Parcel: 12613482A

Address:
4649 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11CM03793
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/21/2011 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied 1. For all new toilet rooms (1st and 2nd levels), please provide large scale floor plans and interior elevations showing all accessible code requirements including dfimesnions, clearance, accessories and fixtures.
2. Provide large scale plan and details of the landing and ramps out the most Westerly exit. Show all accessible code requirements such as landings, dimensions, slopes and handrails including elevations.
3. Detail 1/A3.2; Shorten the 20' ramp to 10'-0" (slope is still less than 1:12) and provide a 5' deep landing at the bottom of the ramp with plenty of room for the required 12" handrail extension on the outside of the ramp. Provide handrail elevations.
4. Please provide Special Inspection Certifications.
5. Detail 2/A3.2:
a. Provide section through stairs showing elevation differences and raiser and tread dimensions plus handrail elevation.
b. Please show grade differentials.
6. Provide large scale detail for the second exit landing, ramps and handrails located on the West side.
END OF REVIEW