Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T11CM03524
Parcel: 105110700

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T11CM03524
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2011 MICHAEL ST. PAUL ZONING REVIEW Approved
11/14/2011 JASON GREEN ENGINEERING REVIEW Approved
11/14/2011 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
11/14/2011 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET A01; FLOOR PLAN: PROVIDE ENLARGED PLANS OF THE RESTROOMS, INDICATING ALL CRITICAL TURNING RADII AND CLEARANCES.
2. SHEETS G01, G02, AND G03: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE.
11/14/2011 ERIC NEWCOMB ADA REVIEW Passed
11/14/2011 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved
11/15/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Revise the duct insulation per Section 503.2.7, IECC 2006, as amended by the City of Tucson.
2. Provide calculations demonstrating adequate ventilation. Reference: Section 403.3, IMC 2006, as amended by the City of Tucson.
3. Revise the size of the condensate drains in accordance with Section 307.2.1, IMC 2006, as amended by the City of Tucson.
11/15/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Clarify which plumbing code has been used for this design; the water and waste fixture units refer to the IPC but the reference code on sheet A00 calls out the UPC. This review has been made using the 2006 UPC.
2. Detail S01/P-3 shows a hot water recirculation system. Coordinate the detail with the proposed plumbing plan. Reference: section 103.2.3, UPC 2006. (Note: a vacuum relief valve is required for the proposed installation. Reference: Section 608.7, UPC 2006.
3. Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported. Reference: Sections 310.0 and 314.5, UPC 2006.
4. The 3" drain pipe downstream of the floor drains is served by a 2" wall cleanout. Provide cleanouts sized per Section 707.11, UPC 2006.
11/15/2011 ROBERT SHERRY WATER REVIEW Approved
11/15/2011 WMOTTO1 FIRE REVIEW Approved
11/21/2011 GERRY KOZIOL WWM REVIEW Approved