The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T11CM03493
Parcel: 107030380

Address:
2510 N JORDAN DR

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM

Permit Number - T11CM03493
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/13/2012 MICHAEL ST. PAUL ZONING REVIEW Denied P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T11CM03493
2510 North Jordan Drive
Addition to SFR


TRANSMITTAL: January 13, 2012


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO).


This Site requires a DDO for the setback to the east property line. This site is in the R-1 Zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator AA (LUC Section 3.2.6.4).

The minimum setback to the east property line is the greater of six feet or two-thirds the height of the structure's wall facing the property line. The wall height does not exceed nine (9) feet. The minimum setback to the east property line is six (6) feet. The proposed setback is zero (0) feet.
01/13/2012 MICHAEL ST. PAUL NPPO REVIEW Passed
06/22/2012 FRODRIG2 BUILDING-RESIDENTIAL REVIEW Needs Review
06/22/2012 GERRY KOZIOL WWM REVIEW Approved
06/22/2012 FRODRIG2 ENGINEERING REVIEW Needs Review