Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T11CM03428
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/18/2011 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED TO SHOW CLOTHES WASHER CONNECTED TO SEWER NEE WW 5TH FLOOR CREDIT EVALUATION |
| 11/23/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 11/29/2011 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 12/01/11 Activity: T11CM03428 Address: 1724 E Miles St Applicant: Bodie Robins Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. SITE PLAN: 1. Specify the location of the electrical service meter and service feeders from utility to the point of attachment on building, R106.1.1. 2. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. All plan pages should reference this code. Appeal to the Building Official for use of the 2003 IRC/UPC. STRUCTURAL / FRAMING PLAN: 3. Clarify the direction of the roof slope above the kitchen area, sheet A8. PLUMBING PLAN: 4. Bathtubs have a water supply fixture unit value of 4 per UPC table 6-6, revise. 5. Show the size and location of all cleanouts, UPC 707.4, Table 7-6. Two-way cleanout required within 2' from the building at the lower end. Cleanouts are required at the kitchen sink area UPC 707.4 W/ State amendment. MECHANICAL PLAN: 6. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. ELECTRICAL PLAN: 7. The receptacle at the end of the peninsula in the kitchen may not share lighting outlet circuit, E3801.3. 8. Show locations of smoke detectors (every sleeping room and hallways leading to). All smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke detectors, R313. 9. Show receptacle outlets at each kitchen counter space wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3801.4.1. (counter space beside refrigerator) INTERNATIONAL ENERGY CONSERVATION: 10. Specify the "R" value of the insulation, as well as the "U" factor and the solar heat gain coefficient of the windows and doors. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing and skylights is U=0.75, ceiling R=30. Mass wall requirement is R=4 when 50% of insulation is exterior and R=6 when applied interior, N1102.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/13/2012 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 02/13/2012 | SUE REEVES | REJECT SHELF | Completed |