Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T11CM03234
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/26/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PREVIOUS COMMENT: PROVIDE THE CODE ANALYSIS INFORMATION ON THE DRAWINGS. THE ACCESSIBILITY CODE IS THE ICC/ANSI A117.1-2003. 2. SHEET 3: REMOVE THE NOTE "HANDICAPPED ACCESSIBLE" ON THE RESTROOM ON THE SOUTH WALL. 3. SHEET 6: ARRANGE THE WATER CLOSET/SINK TO MEET ICC/ANSI A117.1-2003, FIGURE 604.3 SPACE REQUIREMENTS. 4. SHEET 6: ADD A VERTICAL GRAB BAR PER ICC/ANSI A117.1-2003, FIGURE 604.5.1. 5. SHEET 6: LOCATE THE PAPER DISPENSER PER ICC/ANSI A117.1-2003, FIGURE 604.7. 6. SHEET 3: INDICATE THE EXISTING SERVICE SINK IN THE JANITOR ROOM. 7. SHEET 3: INDICATE THE STRUCTURAL INTERIOR WALL AND THE EXISTING DRINKING FOUNTAIN. |
11/01/2011 | FRODRIG2 | WATER | REVIEW | Needs Review | |
11/01/2011 | FRODRIG2 | MECHANICAL-COMMERCIAL | REVIEW | Needs Review | |
11/01/2011 | FRODRIG2 | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
11/01/2011 | FRODRIG2 | WWM | REVIEW | Needs Review |