Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T11CM03206
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET CA-1; CANOPY PLAN: NOTE 2 INDICATES TO SEE STRUCTURAL DRAWINGS FOR THE CONCRETE PAVING. THERE ARE NO CONCRETE SLAB DETAILS AND SPECIFICATIONS FOR THE CANOPY SLAB IN EITHER THE CIVIL OR STRUCTURAL DRAWINGS. PLEASE PROVIDE. 2. SHEET CA-2; FOUNDATION NOTES: NOTE 2 INDICATES A SOIL BEARING CAPACITY OF 3750 PSF. IN REFERENCING THE GEOTECHNICAL REPORT NO ALLOWABLE END BEARING CAPCITY TABLE INCLUDED AS IN THE SPEEDWAY CIRCLE K REPORT. PLEASE PROVIDE. 3. SHEET CA-4; SECTION C: A NOTE INDICATES TO SEE SHEET E1 FOR THE TUBE COLUMN SIZE. REVISE THE NOTE (NO SHEET E1). 4. SHEET CA-4.1; SECTION E: A NOTE INDICATES TO SEE SHEET E1 FOR THE TUBE COLUMN SIZE. REVISE THE NOTE (NO SHEET E1). 5. SHEET CA-7; PLAN 1: ARE ANY OF THE CMU CORES FILLED WITH CONCRETE AND/OR REINFORCING? VERIFY. 6. GENERAL: ALL DEFERRED SUBMITTALS MUST BE APPROVED IN WRITING BY RON BOOSE (BUILDING OFFICIAL) BEFORE THOSE SUBMITTALS WILL BE REVIEWED. RON.BOOSE@TUCSONAZ.GOV. 7. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. END OF REVIEW |
| 10/24/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 10/24/2011 | DAVE MANN | FIRE | REVIEW | Approved | Fire notes: Separate permits are required for tanks. |
| 10/27/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | See comments for T11CM02497. Ray T Majuta Electrical Plan Review PDSD CoT 10/29/11 |
| 10/31/2011 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: 1395 W. Miracle Mile T11CM03206 Building Plan (1st Review) TRANSMITTAL DATE: October 31, 2011 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Zoning can not approve the building plan until the site plan has been approved 3. Due to the numerous comments by other PDSD agencies on the building plan Zoning will approve once all other PDSD agencies have approved. 4. Zoning will re-review the building plan on the next submittal to insure compliance with the approved site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/30/2011 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 11/30/2011 | SUE REEVES | REJECT SHELF | Completed |