| 10/06/2011 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 10-06-11 Activity: T11CM03132 2nd review Address: 3224 E 1st St Applicant: Carl's Service Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. GENERAL REQUIREMENTS: 1. As previously requested, justify roof framing to support proposed equipment (2x4 rafters are insufficient to support a 400 pound unit). Support is needed under unit to an interior wall or significant reinforcement of existing roof framing will be necessary 2. As previously requested, specify total linear feet of gas piping from the meter to the gas pack (1/2" gas piping is insufficient to supply gas pack at a distance greater than 20 feet). If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |