Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T11CM03081
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/21/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
11/22/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | The submitted calculations are for Green Valley, Arizona, not Pima County < 4,000 feet. Provide details for the continuous insulation R-value of 27.6. [Original comment: Provide energy code compliance calculations for the additions to the building envelope; use the climate zone for Pima County < 4,000 feet. Provide sufficient detail on the drawings to evaluate the energy compliance of the additions to the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections 101.4, 101.4.3, and 104.2, International Energy Conservation Code 2006.] |
11/22/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Comment not resolved; show the location and size for each water hammer arrestor. [Original comment: Show size, location, and model number of hammer arrestors to be installed on the cold water system. Reference: Section 604.9, 2006 IPC.] 2. Comment not resolved; the revised drawing now shows one of the drains labeled as both sanitary and grease waste. [Original comment: Clarify waste and vent piping isometric on sheet P-1.0 which drain is "san" and which is "grease waste".] 3. Coordinate the waste and vent diagram with the plumbing plan. [Original comment: Show how the horizontally wet vented fixtures for the two bathrooms, qualifies as a "bathroom group". Reference: chapter two, definition of "bathroom group". Reference 909.1 2006 IPC; horizontal wet vent permitted. Any combination of fixtures within two bathroom groups.... and a bathroom group is defined as a water closet, lavatory, bathtub or shower, including or excluding a bidet, an emergency floor drain or both. Waste and vent piping plan on sheet P1.0 shows three water closets and a urinal.] |
11/29/2011 | CAGUILA1 | ENGINEERING | REVIEW | Needs Review | |
11/29/2011 | CAGUILA1 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
11/29/2011 | CAGUILA1 | ZONING | REVIEW | Needs Review |