Permit Number: T11CM03081
Parcel: 13331159T

Review Status: Completed

Review Details: SITE

Permit Number - T11CM03081
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/12/2011 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 8800 E. Broadway Blvd
T11CM03081
Site Plan (1st Review)

TRANSMITTAL DATE: October 12, 2011

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the areas of expansion and any changes to the site only.

2. D.S. 2-02.2.1.A.8 Provide a dimension for the wheel stop location see LUC Section 3.3.6.8.C.

3. D.S. 2-02.2.1.A.9 Short Term Bike Rack detail shows 27 3/8" from center of rack to center of rack. Note B calls out 48" between racks. Per LUC Section 3.3.9.2.B.6 and 3.3.9.5.B revise the detail to show the correct 48" between racks.

4. D.S. 2-02.2.1.A.12 Provide a width dimension from the proposed accessible vehicle parking space sign to the building. Per D.S. 2-08.5.1.A all sidewalks will be a minimum four (4) foot wide.

5. D.S. 2-02.2.1.A.12 The proposed three (3) sidewalk shown south of the proposed addition does not meet the requirements of D.S. 2-08.5.1.A. A Development Standard Modification Request (DSMR) must be applied for and approved prior to approval of the site plan is approved. If the DSMR is approved provide the following information of the site plan; DSMR number, date of approval, what was modified, and conditions of approval.

6. D.S. 2-02.2.2.A.3 Provide a floor area ratio (FAR) calculation on the plan, see LUC Section 3.2.11.

7. D.S. 2-02.2.2.A.4 Provide a vehicle and bicycle parking calculation that includes the required and provided on the plan. As it appears parking spaces are being removed from the east end of this project the calculation needs to include the entire shopping center.

8. Depending on how the above comments are addressed additional comments may be forth coming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan.
10/12/2011 RBROWN1 ADA REVIEW Passed
10/12/2011 RONALD BROWN H/C SITE REVIEW Approved
10/13/2011 ANDREW CONNOR LANDSCAPE REVIEW Denied Ensure that all Zoning and Engineering comment are addressed.

Additional comments may apply
10/13/2011 ANDREW CONNOR NPPO REVIEW Approved
10/13/2011 JASON GREEN ENGINEERING REVIEW Needs Review
10/13/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
10/14/2011 CPIERCE1 FIRE REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/14/2011 CPIERCE1 OUT TO CUSTOMER Completed