Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T11CM03076
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2012 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | The "T" bar of the ceiling system can not be a component of the wall bracing system. As previously commented the diagonal bracing must be connected directly to the metal stud framing. END OF REVIEW |
| 12/08/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/08/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Refer to the waste and vent riser diagram on sheet MP2 and revise the size of the wall cleanout serving the three shampoo sinks. A 2" waste pipe cannot accommodate a 4" cleanout. In addition, the 2" waste pipe becomes a 3" drain under the slab; the 3" drain will require a 3" cleanout. Reference: Section 707.11 and Table 7-6, UPC 2006. 2. According to the water pressure calculations used for the shell building, the water piping for this building was based on a friction-loss budget of 5.0 PSI per 100 feet (including 15 PSI minimum pressure, and a developed length of 409 feet). Verify the available water service and revise the pipe sizes accordingly. Note that the water velocity for cold water in copper tubing is 8 feet per second and the water velocity for hot water in copper tubing is 5 feet per second. Reference: Section 610.12 and Appendix A, UPC 2006. |
| 12/08/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Correct the basic ventilation calculations: 525 square feet with 25 people per 1,000 square feet results in a population of 13, not 8 people. [Original comment: Revise the ventilation calculations, matching the occupation classifications from Table 403.3, IMC 2006 with the occupancy descriptions shown on the drawing (e.g. beauty salon, with 25 CFM per person and 25 people per 1,000 square feet). Reference: Sections 403.3 and 403.3.2, IMC 2006.] 2. Comment not addressed. Provide calculations to show that the common ventilation system is sized in accordance with Section 403.3.2, IMC 2006. |
| 12/12/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/10/2012 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 01/10/2012 | GERARDO BONILLA | REJECT SHELF | Completed |