Permit Number: T11CM03053
Parcel: 11901006A

Address:
690 E 36TH ST

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T11CM03053
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/19/2011 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. PREVIOUS COMMENT: GENERAL: PROVIDE STRUCTURAL NOTES ON THE DRAWINGS FOR MATERIALS, LOADINGS, FOUNDATIONS, ETC.
2. PREVIOUS COMMENT: GENERAL: PROVIDE ARCHITECTURAL SPECIFICATIONS AS REQUIRED.
10/19/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the size of the primary and overflow scuppers to comply with the requirements of Section 1101.11.2.1, UPC 2006 (minimum size 6.3" wide x4" high).
10/19/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Comment not resolved. The U-factors and the SHGC for the glazing does not meet the requirements of the prescriptive values (section 502, IECC 2006) and while the drawing calls out 1/4" glazing, the U-Factor chart refers to 1" glazing. Provide energy code compliance calculations or show that the addition complieswith the prescriptive requirements. [Original comment: Provide energy code compliance calculations for the building envelope; use the climate zone for Pima County < 4,000 feet. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006.]
2. Comment not addressed. Provide structural calculations to verify that the roof is capable of supporting the roof top unit. Reference: Section 302.1, IMC 2006.
10/20/2011 CPIERCE1 WWM REVIEW Needs Review
10/20/2011 CPIERCE1 ZONING REVIEW Needs Review
10/20/2011 CPIERCE1 FIRE REVIEW Needs Review
10/20/2011 CPIERCE1 ENGINEERING REVIEW Needs Review