Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T11CM03013
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 1-22-13 Activity: T11CM03013 Address: 2408 S Tucson Sv Applicant: John & Rachel Lopez Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. SITE PLAN: 1. Designate the new location of the proposed gas meter, R106.1.1. FLOOR PLAN: 2. Specify nonabsorbent wall surface minimum 6' above the floor with cement, fiber-cement, or glass-mat board backing in tub/shower enclosures, R307.2, R702.4.2. 3. Show the location of attic access min. 22"x30", R807. 4. Provide impact protection for appliances located in garages, M1307.3.1. 5. Doors between a garage and a residence shall be self-closing minimum 20-minute fire-rated, R302.5.1 as amended. 6. Provide ½" gypsum board on all walls common to the garage and house in compliance with R302.6. 7. Gas appliances installed in garages shall be mounted on platforms at least 18" above the floor, M1307.3. STRUCTURAL / FRAMING PLAN: 8. Provide a roof framing plan that includes roof framing materials and spacing, header or lintel support over all wall openings and section references to the applicable details, R801.2. SECTIONS - DETAILS: 9. Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. PLUMBING PLAN: 10. Provide a water fixture unit schedule for the entire property (including existing) P2903.6. 11. Provide the maximum developed length of water line from the meter the furthest appliance served, the water meter size, lowest available pressure (including pressure loss calculations), the diameter of the water service line, P2903.7. 12. Provide note requiring that water hammer arrestor be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, IRC P2903.5. 13. Provide a gas line isometric and size the supply pipe for the connected demand. Include the length of line and BTU demand for each appliance, size of each branch, total demand, and total developed length from meter to the most remote appliance on the system, G2413.1, Table G2413.4 (1). 14. Provide pressure and temperature relief valve for the water heater terminating to the exterior facing no more than 6 above the grade, P2803.6.1. 15. Specify water conservation requirements: Water closets = 1.6 gallons per flush, Sinks = 2.2 gpm, Showerheads = 2.5 gpm, P2903.2. 16. Shower and tub/shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type. MECHANICAL PLAN: 17. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1. ELECTRICAL PLAN: 18. Provide an electrical riser diagram with grounding method and bonding to metallic piping, E3303, E3507. 19. Island or peninsula counter tops with a long dimension of 24" and a short dimension of 12" or greater shall have at least one receptacle, E3801.4.2. 20. Bedroom outlets shall be protected with combination-type arc-fault breakers (receptacles, lights, and smoke detectors), E3802.12. 21. Show locations of smoke detectors in hallways leading to sleeping rooms, R313. OUTDOOR LIGHTING CODE 22. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. 23. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). INTERNATIONAL ENERGY CONSERVATION CODE: 24. Indicate the insulation material that will provide R-19 in a 2x4 wall cavity. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/21/2013 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |
| 02/21/2013 | CPIERCE1 | REJECT SHELF | Completed |