Permit Number: T11CM02883
Parcel: 11706081A

Address:
290 E 8TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11CM02883
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/22/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. If the water service, trench drain, sand/oil separator, and sewer connection were installed under a separate contract, provide the reference drawings and the City of Tucson permit number under which the items were installed. [Original comment: Provide a plumbing design for the wash bay, including the water source, the drainage fixtures and piping, and sand-oil separator plans. Revise the site utility drawing (C2.4) to include this structure. Reference: Section 103.2.3, UPC 2006.]
2. Provide a low-pressure cutoff and inlet pressure gauge for the booster pumps. Reference: Section 609.8, UPC 2006.
3. PVC pipe is not approved for water distribution use within a building. Reference: Section 604.1, UPC 2006.
11/22/2011 GERRY KOZIOL WWM REVIEW Denied NEED TO SHOW LOCATION/METHOD OF CONNECTION TO PUBLIC SEWER. NEED RD FLOOR PCRWRD REVIEW OF LOCATION/METHOD OF CONNECTION TO PUBLIC SEWER- CHAD AMATEAU- 740-6547 MAY NEED PUBLIC SEWER CONSTRUCTION PERMIT FOR PUBLIC SEWER ALTERATIONS- YVONNE SUAREZ - 740-6733
NEED PCRWRD 3RD FLOOR CAPACITY REVIEW - KURT STEMM - 740-6534
NEED WASTEWATER IWC REVIEW & APPROVAL - TOM TOMCHAK - 5025 W INA RD - 4436200
11/28/2011 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
12/02/2011 LOREN MAKUS ENGINEERING REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/08/2011 SUE REEVES OUT TO CUSTOMER Completed
12/08/2011 SUE REEVES REJECT SHELF Completed