Permit Number: T11CM02826
Parcel: 117031460

Address:
820 N PERRY AV

Review Status: Active

Review Details: PLANS OK TO SUBMIT - RES

Permit Number - T11CM02826
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/31/2011 ANY ENGINEERING REVIEW Active
08/31/2011 ANY NPPO REVIEW Active
08/31/2011 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Needs Review
12/28/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD Zoning Review Transmittal

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: T11CM02826
820 & 822 N. Perry Avenue

TRANSMITTAL DATE: December 28, 2012

Proposed project - Expansion of the unit at 822 N. Perry Ave.

COMMENTS:
Site Plan OK D.D.O. required for: Street Perimeter yard setback from the proposed awning to the street perimeter yard property line and from the existing building to the south perimeter yard property line.

Per LUC Section 3.2.6.5.A Within established areas, the front street perimeter yard is twenty (20) feet or one and one-half (1 1/2) the height of the proposed wall (H), measured from the street property line, whichever is greater. Based on a wall height of 13.3' the required street perimeter yard is 20.0', proposed perimeter yard from 2.0' back of the propose cantilevered awning is 10.0'.

Per LUC Section 3.2.6.4 development designator "P", perimeter yard indicator "CC" the required perimeter yard is ten (10) feet or three quarters (3/4) the height of the proposed exterior wall (H), whichever is greater: Based on a wall height of 13.3' the required perimeter yard for the existing building is 10'-0". See the following for the proposed perimeter yard setbacks for each proposed porch, proposed perimeter yard is 7.5'.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
12/28/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD Zoning Review Transmittal

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: T11CM02826
820 & 822 N. Perry Avenue

TRANSMITTAL DATE: February 8, 2013 (Revised)

Proposed project - Expansion of the unit at 822 N. Perry Ave.

COMMENTS:
Site Plan OK D.D.O. required for: Street Perimeter yard setback from the proposed awning and porch to the street perimeter yard property line and from the existing building to the south perimeter yard property line.

Per LUC Section 3.2.6.5.A Within established areas, the front street perimeter yard is twenty (20) feet or one and one-half (1 1/2) the height of the proposed wall (H), measured from the street property line, whichever is greater. Based on a wall height of 13.3' the required street perimeter yard is 20.0', proposed perimeter yard from 2.0' back of the propose cantilevered awning is 10.0' and 13'-4" to the proposed porch.

Per LUC Section 3.2.6.4 development designator "P", perimeter yard indicator "CC" the required perimeter yard is ten (10) feet or three quarters (3/4) the height of the proposed exterior wall (H), whichever is greater: Based on a wall height of 13.3' the required perimeter yard for the existing building is 10'-0". See the following for the proposed perimeter yard setbacks for each proposed porch, proposed perimeter yard is 7.5'.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956