Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T11CM02815
Parcel: 125051110

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T11CM02815
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/08/2011 STEVE SHIELDS ZONING REVIEW Denied PDSD Zoning Review Transmittal

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: T11CM02814
2242 E. 4th Street

TRANSMITTAL DATE: September 8, 2011

Proposed Project: Main House - Arizona Room addition.
Sleeping Quarters - Carport addition
COMMENTS:
Site Plan OK D.D.O. required for: Perimeter yard setbacks from the proposed bath to the west perimeter yard property line.

Per LUC Section 3.2.6.4, R-1 Zone, Development Designator "G", Perimeter Yard Indicator "AA" the required perimeter yard setback is 6.0' or 2/3 the height of the exterior wall.
Main House - Arizona Room addition
1. Based on an exterior wall height of 8-6" the required perimeter yard setback from the proposed Arizona Room to the west property line is 6'-0, proposed setback is 4'-6".
Sleeping Quarters - Carport addition
2. Based on an exterior wall height of 8-6" the required perimeter yard setback from the proposed Carport to the east property line is 6'-0, proposed setback is 4'-6".
3. Based on an exterior wall height of 8-6" the required perimeter yard setback from the proposed Carport to the south property line is 6'-0, proposed setback is 5'-6". Roof overhang of 3'-6" proposed therefore setback is measured to max of 2'-0" of roof overhang.
If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov (520) 837-4956
09/08/2011 SSHIELD1 NPPO REVIEW Passed
10/20/2011 GBONILL1 ENGINEERING REVIEW Needs Review
10/20/2011 GBONILL1 BUILDING-RESIDENTIAL REVIEW Needs Review