Permit Number: T11CM02699
Parcel: 11706081A

Address:
290 E 8TH ST

Review Status: Completed

Review Details: SITE

Permit Number - T11CM02699
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2011 RBROWN1 ADA REVIEW Denied SHEET 2.2
1. Please identfy the two marked crossings with painted stripes or some other means to differientate the crossing from the concrete and brick paving.
2. At note 38, change the DTL 207 reference to ADAAG, Sections 4.29.2, 4.29.5 and A4.29.
3. The curb ramp and detectable warning shown at the South end of the most Northerly marked crossing is not the same as the detail that is referenced by note 7, 5/8.3. Please provide a detail for this particular curb ramp.
SHEET C2.3
4. As per the spot grades shown in the accessible parking space and ailse, the surface slopes exceeds 2% which is in non compliance with ADAAG, Section 4.6.3.
5. Ditto comment 1.
SHEET 8.1
6. Detail 1:
a. The 2% grade slope is for all directions as per Section 4.6.3.
b. The bottom of the main accessible parking sign is to be 7'-0" as per DOT sign standards.
SHEET 8.3
7. At details 4, 5 and 8 change the reference to DTL 207 to ADAAG, Sections 4.29.1., 4.29.5 and A4.29.
END OF REVIEW
09/09/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
09/09/2011 RONALD BROWN H/C SITE REVIEW Passed This is a COT owned and operated project. Reference ADA folder for accessible comments.
09/13/2011 DAVE MANN FIRE REVIEW Approved
09/13/2011 ANDREW CONNOR NPPO REVIEW Approved
09/13/2011 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond
09/13/2011 CRAIG GROSS ZONING REVIEW Approved
09/13/2011 LOREN MAKUS ENGINEERING REVIEW Denied Floodplain use permit required.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/30/2011 SUE REEVES OUT TO CUSTOMER Completed
09/30/2011 SUE REEVES REJECT SHELF Completed