Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T11CM02448
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/18/2011 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 08/18/2011 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 8-18-11 Activity: T11CM02448 Address: 2102 S Oak Park Dr. Applicant: Alvaro Brassea Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. FLOOR PLAN: 1. Show emergency escape/rescue openings for master bedroom, R310. Minimum net opening of 5.7square feet for floors above grade level, 5 square feet for floors at grade level. Maximum sill height = 44". Minimum clear opening = 24" high x 20" wide. SECTIONS - DETAILS: 2. Specify location of grade or paving on cross section. Show stucco weep screed with a min. clearance 4" above grade or 2" above paved areas, R703.6.2.1. PLUMBING PLAN: 3. Provide a water fixture unit schedule for the entire property (including existing) P2903.6. 4. Provide the maximum developed length of water line from the meter the furthest appliance served, and the diameter of the water service line, P2903.7. ELECTRICAL PLAN: 5. Laundry rooms require at least one 20-amp circuit that shall serve no other outlets, E3603.3, 3801.8. 6. Provide at least one wall switch controlled light at outdoor entrances or exits, E3803.3. 7. Provide a scaled and legible electrical layout for the Arizona room. INTERNATIONAL ENERGY CONSERVATION CODE: 8. The simplified prescribed energy values for ceilings is R=30, N1102.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/22/2011 | SUE REEVES | APPROVAL SHELF | Completed |
| 08/22/2011 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |