Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T11CM02366
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/08/2011 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 09/29/2011 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007 and the 2006 UPC with amendments on 7/10/2007. For initial construction: Effective 1/1/2007 the Inclusive Home Design; starting 3/1/2009 Solar Water Preparation and 7/1/2009 Solar Photo-Voltaic Preparation are required for all new SFR and duplex plans. Show the code references on the plans. Amendments to adopted codes are at the City web-site http://www.tucsonaz.gov: Planning, Building, & Business; under the Building topic; Building Ordinances and Codes; Building Codes GENERAL NOTES: " Provide legible notation (minimum 3/32" lettering) sheet #a4 & a5. STRUCTURAL PLANS: 1. Provide a means of load bearing at the master bathtub window opening for supporting the headers at the corner, R301.1. 2. Provide an interior wall opening header schedule consistent with Table 502.5(1) & (2). SECTIONS - DETAILS: 1. Clarify the roof drain openings reference Detail 1 or 2 (drain or scupper) at the Guest Bedroom and Study areas. Shown as supper, but referenced as drain. 2. Provide the details (sheet #a11) referenced on sheet #a7, R106.1.1. 3. Notate and specify the size, spacing and length of anchor bolts for sill plates, top plates and ledgers, R403.1.6. 4. Show the ceiling gypsum board as either 5/8" or ½" sag resistant (sheet #a7) when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d. 5. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2. 6. Show the weep screed with a minimum clearance 4" above grade or 2" above paved areas, R703.6.2.1. This may require a design with concrete stems. 7. Show rafter (truss) to wall connection using (H2.5) ties having a resistance to uplift of not less than 365 pounds, R802.11.1. (City of Tucson Amended). PLUMBING PLANS: 1. Provide a complete plumbing design and indicate which code is used, 2006 UPC or 2006 IRC. 2. Show a pressure and temperature relief valve at the water heater. Note a metallic T&P line terminating at the exterior 6 inches above grade facing down, UPC 608.5. P2803.6.1. 3. Provide a water hammer arrester wherever quick-closing valves (clothes washer, dishwasher and refrigerator) are installed in a water distribution system, UPC 609.10. P2903.5. 4. Provide pipe sizes (diameter & length), average pressure and a complete fixture unit schedule UPC 610.8, Table 6-5. P2903.6. Show the meter size and pipe diameter between the meter and shut off valve in compliance with Table 6-6, P2903.7. The existing yard water pipe may require replacement with larger sizes for controlling excessive water flow rates, UPC 610.8, Table 6-6. P2903.7. 5. Show a two-way cleanout at the building exterior, UPC 719.0. P3005.2. 6. Show plumbing vents (VTR) within acceptable distances from traps, UPC Table 10-1. P3111.3. 7. Provide gas pipe sizes in compliance with connected demand, UPC 1217.2, & Table 12-8. G2413.3 & Table G2413.4(1). MECHANICAL PLANS: 1. Provide a complete Mechanical design. 2. Provide heating facilities in all habitable rooms, R303.8. 3. Provide an equipment specification list including the furnace, M1302.1. 4. Provide return air duct and register sizes meeting minimum requirements of 72 SQ IN/ ton, M1403. Minimum duct/register size: heat pump or air conditioner - 6 SQ IN per 1,000 BTU (1 ton cooling = 12,000 BTU). 5. Show dryer vent size and location for venting to exterior, M1501. 6. Show that the maximum length of dryer vent does not exceed 25' with consideration of bend reductions, M1502. 7. Show bathroom (toilet room) exhaust fan locations for venting to exterior with minimum 50 CFM rating R303.3 and M1507.3. 8. Show a return air register serving the Great Room, M1601. 9. Show combustion air compliance for the water heaters with two interior area openings of 1 SQ IN for each 1,000 BTU rating and minimum of two 100 SQ IN openings, one within 12" of top and other 12" of bottom, G2407.5.3.1. ELECTRICAL PLANS: 1. Smoke alarms are required outside each separate sleeping area, R313.2. Show a smoke alarm on the outside of the Guest Bedroom doors. 2. Provide a panel schedule showing wire size of each circuit or notate the wire size for each protection rating, E3602.2. 3. Designate the circuit number at the location of each light fixture, E3603.5. 4. Protect bedroom outlets including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3802.12. 5. Specify recessed lighting with 3" separation from combustibles or IC listing, R808, and compliance with energy efficiency leakage, N1102.4.3. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/04/2011 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 10/04/2011 | SUE REEVES | REJECT SHELF | Completed |