| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2011 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 07/28/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide information on the sequence of operation for the restroom exhaust fans to show that all of the air supplied to the restrooms will be exhausted (e.g. evenif. Reference: Section 403.2.1 (4), IMC 2006 |
| 07/28/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
| 07/28/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 07/28/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A9; ELEVATION 3 (EXTERIOR TOILET ROOM): A DETAIL REFERENCES 11/A9 FOR A CAP. THIS IS INCORRECT. REVISE. 2. THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. SEVERAL LOCATIONS ON THE PLANS DO NOT MEET THIS REQUIREMENT. REVISE. 3. SHEET A8; WALL BRACING: PROVIDE BRACING DETAILS FOR PARTITION WALLS THAT ARE NOT FULL HEIGHT (SEE WALL SCHEDULE ON A1.2 FOR LOCATION). |
| 07/28/2011 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 07/28/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Show how the hot water for the lavatories will be limited to a maximum temperature of 110 degrees Fahrenheit. 2. Provide vacuum relief for the storage-type water heater located above the hot water outlets. |
| 07/28/2011 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 07/28/2011 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 07/28/2011 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 07/28/2011 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |