Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T11CM02290
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/19/2011 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
07/19/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
07/20/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
07/20/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide justification for the amount of ventilation provided to the therapy room (equal to an office). |
07/20/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. GENERAL: PROVIDE SITE PLAN PER CITY OF TUCSON SUBMITTAL REQUIREMENTS. 2. SHEET TS.1; GENERAL NOTES (APPLICABLE CODES): ICC/ANSI IS 2003 EDITION. REVISE. 3. SHEET TS.1; GENERAL NOTES: REMOVE ALL ORO VALLEY AND GOLDER RANCH REFERENCES IN NOTE 10. 4. SHEET TS.1; GENERAL NOTES: REVISE COUNTY IN NOTE 1. |
07/20/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
07/20/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Note: this review has been done using the 2006 UPC based on note 1 on the General Plumbing Notes. 1. Revise the size of the wet vent serving P-1 and P-3 per Section 908.2, UPC 2006. 2. Vertical wet venting is limited to 1 and 2 fixture unit fixtures; a clothes washer does not qualify for this use. reference: Section 901.1, UPC 2006. 3. Provide a vacuum relief valve for the water heater per Section 608.7, UPC 2006. |
07/20/2011 | DAVE MANN | FIRE | REVIEW | Approved | |
07/20/2011 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
07/20/2011 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
07/25/2011 | CPIERCE1 | WWM | REVIEW | Needs Review |