Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T11CM02131
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/06/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Please provide a structural detail and calculations that will support the head of the curtain wall as required by manufacturer at detail 17/A2.1. END OF REVIEW |
| 10/17/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Comment not addressed. Revise the piping configuration of the water heater detail on sheet P0.1 to show the hot water return piping routed to the cold water inlet pipe of the water heater, terminating between the shut off valve and the check valve on the cold water inlet. [Original comment: Revise the piping configuration of the water heater detail on sheet P0.1 to show the hot water return piping routed to the cold water inlet pipe of the water heater. Reference: Section 607.2.3, IPC 2006.] 2. Comment not addressed. Provide structural calculations for the water heater shelf design shown on sheet P0.1. [Original comment: Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported. Reference: Section 307.1, IPC 2006.] 3. Comment not addressed. Revise the water heater detail to show the vacuum relief valve located per the manufacturer's listing; between the water heater and any valves on the cold water inlet. [Original comment: Show how the specified water heater, WH-1, complies with the requirements of Section 504, IPC 2006. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/20/2011 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 10/20/2011 | SUE REEVES | REJECT SHELF | Completed |