Permit Number: T11CM02131
Parcel: 12809006B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11CM02131
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/06/2011 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied 1. Please provide a structural detail and calculations that will support the head of the curtain wall as required by manufacturer at detail 17/A2.1.
END OF REVIEW
10/17/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not addressed. Revise the piping configuration of the water heater detail on sheet P0.1 to show the hot water return piping routed to the cold water inlet pipe of the water heater, terminating between the shut off valve and the check valve on the cold water inlet. [Original comment: Revise the piping configuration of the water heater detail on sheet P0.1 to show the hot water return piping routed to the cold water inlet pipe of the water heater. Reference: Section 607.2.3, IPC 2006.]
2. Comment not addressed. Provide structural calculations for the water heater shelf design shown on sheet P0.1. [Original comment: Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported. Reference: Section 307.1, IPC 2006.]
3. Comment not addressed. Revise the water heater detail to show the vacuum relief valve located per the manufacturer's listing; between the water heater and any valves on the cold water inlet. [Original comment: Show how the specified water heater, WH-1, complies with the requirements of Section 504, IPC 2006.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/20/2011 CINDY AGUILAR OUT TO CUSTOMER Completed
10/20/2011 SUE REEVES REJECT SHELF Completed