Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T11CM01902
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/14/2011 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 09/20/2011 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Provide previous approved site and landscape plans for reference. If no plans exist then this submittal will become the document of record. Provide the following information if necessary: " Location, size, and name of existing vegetation to remain in place and new plantings " Both the proper and common name of each type of plant material. Note: Existing development on the site is subject to the zoning regulations in effect at the time the existing development received zoning approval per LUC 3.7.1.2.B 2. Ensure that all zoning comments and concerns are addressed 3. Additional comments may apply |
| 09/23/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 09/27/2011 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, Engineering and Floodplain Review, 09/27/2011 The following comments were provided for the previous submittal, but they do not appear to have been addressed. Address the comments and provide a detailed response letter with the next submittal: 1. The existing and future sight visibility triangles including their dimensions (D.S. 2-02.2.1.A.10). 2. The width of driveways and parking area access lanes (PAALs) (D.S. 2-02.2.1.A.11). 3. Vehicular, bicycle, pedestrian, and handicapped circulation clearly identified (D.S. 2-02.2.1.A.12). 4. Site drainage patterns including the roof drainage, the building finish floor elevation and the site finish grades (D.S. 2-02.2.1.A.16). 5. The estimated cut and fill quantities (D.S. 2-02.2.1.A.17). 6. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way (D.S. 2-02.2.1.A.19). 7. All easements of record must be graphically shown on the plan together with recording docket and page reference (D.S. 2-02.2.1.A.20). 8. Dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines (D.S. 2-02.2.1.A.21). 9. Existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number (D.S. 2-02.2.1.A.23). 10. Fences, walls, or vegetation for screening by type, material, height, location, and spacing (D.S. 2-02.2.1.A.27). 11. Legends and symbols used in the preparation of the site plan shall be in accordance with City of Tucson Drafting Standards. (D.S. 2-02.2.1.B). Resubmittal Required: Revised Site Plan |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/07/2011 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |