Permit Number: T11CM01902
Parcel: 13329015B

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T11CM01902
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/12/2011 DAVE MANN FIRE REVIEW Approved
09/14/2011 TERRY STEVENS ZONING REVIEW Approved
09/14/2011 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
09/15/2011 ERIC NEWCOMB ZONING HC REVIEW Approved
09/23/2011 ROBERT SHERRY WATER REVIEW Approved
09/23/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
09/23/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied Comment not resolved. The envelope energy calculations were performed using the town of Pima in Graham County and the component descriptions on the energy calculations do not appear to correspond to the building shown on the drawings. Include the specifications for the windows and glazed doors on the drawings. [Original comment: Provide energy code compliance calculations for the building envelope using the climate zone for Pima County < 4,000 feet. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006.]
09/27/2011 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 09/27/2011,

The building plan can not be approved until the site plan is approved.
10/03/2011 GERRY KOZIOL WWM REVIEW Denied NEED ADDRESSING REVIEW- SEPARATE LOT
NEED TO SHOW LOCATION/METHOD OF CONNECTION TO PUBLIC SEWER

Final Status

Task End Date Reviewer's Name Type of Review Description
10/07/2011 FERNE RODRIGUEZ OUT TO CUSTOMER Completed