Permit Number: T11CM01744
Parcel: 140280170

Address:
2209 E GINTER RD

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T11CM01744
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/08/2011 MARTIN BROWN FIRE REVIEW Approv-Cond Site plan OK. For building approval by Fire Department, please include the following fire sprinkler design criteria to the plans.
1. Flow data (static pressure, residual pressure, GPM)
Available from the Fire Department (520) 837-7029 or 837-7030.
2. The standard to be used in development of sprinkler system. (NFPA 13, NFPA 13R, or NFPA 13D)
3. The hazard classification of the building, including any special hazards.
4. The density required of the water supply.
07/08/2011 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. A 5' wall is required to screen the adjacent residential property per LUC Table 3.7.2-I. Identify screening element on the site and landscape plans.

2. All walls required by this Division must be of masonry material or masonry with a stucco or textured finish.

3. Detention/retention basins not integrated with paved vehicular use areas shall be landscaped to enhance the natural configuration of the basin. Landscaping is required along retention basin side slopes, bottom and periphery. Plant materials used in basins shall withstand periodic inundation. A minimum of 20 trees per acre must be provided, 33% of tress shall be 24" box or larger. A minimum of 2 shrubs for each tree is required per DS 10.01. Revise landscape plan to include basin(s) treatment.

4. Revise Water Budget calculation if necessary.

5. Comments can be addressed with an over the counter review. Contact via e-mail Andrew.Connor@tucsonaz.gov or by phone: 520-837-4950 for appointment
07/08/2011 ANDREW CONNOR ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Andrew Connor: Landscape and Zoning Review Section

PROJECT: T11CM01744

TRANSMITTAL DATE: 06/10/2011

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
DSD TRANSMITTAL

1. Provide zoning setbacks for stairway to the west of the proposed building and water storage containers for future reference on the site plan.

2. Provide Long-term bicycle parking facilities per criteria found in LUC 3.3.9.4

3. Comments can be addressed with an over the counter review. Contact via e-mail: Andrew.Connor@tucsonaz.gov or by phone: 520-837-4950 for an appointment

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
07/12/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
07/12/2011 LEERAY HANLY H/C SITE REVIEW Approved
07/13/2011 LOREN MAKUS ENGINEERING REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
07/18/2011 DELMA ROBEY OUT TO CUSTOMER Completed