Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T11CM01741
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/03/2011 | CARL SCHULTZ | FIRE | REVIEW | Approved | |
| 06/03/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide calculations to show that adequate ventilation is being provided. |
| 06/03/2011 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Denied | PROVIDE INFORMTION FOR PROPER TERMINATION OF REMOVED ELECTRICAL DEVICES PROVIDE DETAILS FOR NEW LIGHTING, INCLUDING CORRECT IECC COMPLIANCE INFORMATION |
| 06/03/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 06/03/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A1.0: THIS PLAN HAS EXITING ISSUES. IF WE ARE CONSIDERING THE DOORS ON THE SOUTH WALL AS EXITS, EGRESS THROUGH A MERCANTILE STOCKROOM MUST MEET THE FOUR REQUIREMENTS OF THE IBC SECTION 1014.2 (2.1, 2.2, 2.3, AND 2.4). IF WE ARE JUST USING THE EXIT ON THE NORTH WALL, THE MAXIMUM TRAVEL DISTANCE FOR ONE EXIT PER IBC TABLE 1019.2 IS 75 FEET. THAT DISTANCE IS EXCEEDED ON THIS PLAN. CLARIFY AND REVISE THE PLAN. 2. PER THE IBC, TABLE 2902.1, A HIGH/LOW DRINKING FOUNTAIN (OR SINGLE POINT-OF-USE DISPENSER) IS REQUIRED, AND A MOP SINK IS REQUIRED. VERIFY. 3. PER THE IBC, SECTION 3409.7, INDICATE ON THE PLANS HOW A MAXIMUM OF 20% OF THE PROJECT BUDGET IS BEING SPENT ON ACCESSIBILITY ISSUES. |
| 06/03/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide the minimum plumbing facilities required by Table 2902.1, IBC 2006, for mercantile occupancy. 2. Show how the existing plumbing will be capped when the existing sink is removed. |
| 06/03/2011 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | 1. SHEET A1.0: THIS PLAN HAS EXITING ISSUES. IF WE ARE CONSIDERING THE DOORS ON THE SOUTH WALL AS EXITS, EGRESS THROUGH A MERCANTILE STOCKROOM MUST MEET THE FOUR REQUIREMENTS OF THE IBC SECTION 1014.2 (2.1, 2.2, 2.3, AND 2.4). IF WE ARE JUST USING THE EXIT ON THE NORTH WALL, THE MAXIMUM TRAVEL DISTANCE FOR ONE EXIT PER IBC TABLE 1019.2 IS 75 FEET. THAT DISTANCE IS EXCEEDED ON THIS PLAN. CLARIFY AND REVISE THE PLAN. 2. PER THE IBC, TABLE 2902.1, A HIGH/LOW DRINKING FOUNTAIN (OR SINGLE POINT-OF-USE DISPENSER) IS REQUIRED, AND A MOP SINK IS REQUIRED. VERIFY. 3. PER THE IBC, SECTION 3409.7, INDICATE ON THE PLANS HOW A MAXIMUM OF 20% OF THE PROJECT BUDGET IS BEING SPENT ON ACCESSIBILITY ISSUES. |
| 06/03/2011 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 06/21/2011 | CPIERCE1 | WWM | REVIEW | Needs Review | |
| 06/21/2011 | CPIERCE1 | ZONING | REVIEW | Needs Review | |
| 06/21/2011 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review |