Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T11CM01723
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/08/2011 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED COT REVIEW & APPROVAL OF GREYWATER SYSTEM NEED 2 WAY VALVE ON GREYWATER SYSTEM TO CHANEL WATER TO SEWER OR LANDSCAPE |
| 06/30/2011 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 7-1-11 Activity: T11CM01723 Address: 514 E 1st St Applicant: Gal Witmer Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. STRUCTURAL / FRAMING PLAN: 1. Provide section view and details for proposed chimney, R801.2. 2. Specify lumber grade/species, or manufacturer and series for "I" joists, R802.1. PLUMBING PLAN: 3. Provide vent piping through the roof so that the aggregate cross-sectional area shall not be less than that of the largest required building sewer, UPC 904.1. 4. ELECTRICAL PLAN: 5. Show receptacle outlets at each kitchen counter space wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3801.4.1. 6. Island or peninsula counter tops with a long dimension of 24" and a short dimension of 12" or greater shall have at least one receptacle, E3801.4.2. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/18/2011 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 07/18/2011 | SUE REEVES | REJECT SHELF | Completed |