Review Date Reviewer's Name Type of Review Description Status Comments
06/06/2011 DAVID RIVERA ZONING REVIEW Approv-Cond
06/06/2011 LEERAY HANLY MECHANICAL-COMMERCIAL REVIEW Approved
06/06/2011 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Approved
06/06/2011 LHANLY1 WATER REVIEW Approved
06/06/2011 LEERAY HANLY BUILDING-COMMERCIAL REVIEW Denied PP C1--- DELETE IRC REFERENCES FROM CODE ANALYSIS

PP A-1

a) DELETE REFERENCE TO IRC AT STEPS

b) DETAIL A--CONSIDER ADDING PROVISIONS FOR EXPANSION AND CONTRACTION AT TOP OF WALL.

c) DETAIL C -- SPECIFY FIRE RETARDANT TREATED WOOD FOR TYPE IIA CONSTRUCTION

d) DELETE REFERENCES TO IRC IN GENERAL NOTES

e) PROVIDE DIMENSIONED DETAILS, DETAIL REFERENCES FOR HANDRAILS, FIREPLACES, FIRE-PITS, CABINETRY, ETC. PROVIDE CUT-SHEETS FOR PREMANUFACTURED FIREPLACES, FIRE-PITS, ETC.

PP A-3

a) PROVIDE DETAILS AND CUT SHEETS FOR FIREPLACE AND SOLAR TUBES. DETAILS TO INCLUDE MOUNTING, CEILING & ROOF PENTRATIONS & FLASHING AT ROOF PENETRATIONS.

b) THERE ARE REFERENCES WHICH WERE CUT OFF OF RIGHT SIDE OF PLAN VIEW DURING PRINTING.
06/06/2011 CARL SCHULTZ FIRE REVIEW Denied According to IFC 907.2.9 need to install a fire alarm system
06/06/2011 LEERAY HANLY PLUMBING-COMMERCIAL REVIEW Approved
06/06/2011 LEERAY HANLY ADA REVIEW Passed
06/07/2011 GERRY KOZIOL WWM REVIEW Approved
06/10/2011 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
06/13/2011 CPIERCE1 OUT TO CUSTOMER Completed
06/13/2011 SUE REEVES REJECT SHELF Completed