Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T11CM01714
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/02/2011 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
06/02/2011 | LEERAY HANLY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
06/02/2011 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
06/02/2011 | LHANLY1 | WATER | REVIEW | Passed | |
06/02/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PER THE 2006 IBC, SECTION 1607.13, INTERIOR WALLS MUST BE DESIGNED TO RESIST A HORIZONTAL LOAD OF 5 PSF. PROVIDE A DETAIL AT THE TOP OF THE WALL AND AT THE STRUCTURE ABOVE, INDICATING DIAGONAL BRACING. INDICATE SIZE AND SPACING OF THE BRACING, HOW IT IS CONNECTED TO THE STRUCTURE ABOVE, AND HOW IT IS CONNECTED TO THE TOP OF THE WALL. |
06/02/2011 | LHANLY1 | WWM | REVIEW | Passed | |
06/02/2011 | LEERAY HANLY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
06/02/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
06/02/2011 | DAVE MANN | FIRE | REVIEW | Approved | |
06/02/2011 | RONALD BROWN | ADA | REVIEW | Passed | |
06/02/2011 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/03/2011 | SUE REEVES | OUT TO CUSTOMER | Completed |