Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T11CM01665
Parcel: 10321029Y

Review Status: Completed

Review Details: OTHER

Permit Number - T11CM01665
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/01/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not resolved; provide additional cleanouts for aggregate horizontal changes in direction of over 135 degrees. [Original comment: Provide cleanouts for the indirect waste pipe from P-5 per Sections 707.4 and 707.5, UPC 2006. Reference: Section 803.0, UPC 2006.]
2. Comment not addressed. Provide roof drainage calculations and plans. All roof areas shall be drained by roof drains, scuppers, or gutters. Provide dimensions of scuppers, downspouts, etc. Reference: Section 1101.11.1, UPC 2006.
3. Comment not resolved; changes were made to the gas piping plans on sheet P1.2 but nothing was corrected on sheet P2.0. Also, the location of AC-1 and AC-2 are reversed on the gas diagram (1/P2.0). [Original comment: Clarify the natural gas piping system. One existing AC unit is noted as having an input of 60 CFH on the Gas Meter Load table but 72 CFH on the Gas Diagram and on sheet P1.2. Also, the natural gas piping system is noted as having a developed length of 120 feet but the longest noted length is shown as 93 feet.]
4. Comment not resolved; the pipe size was changed on sheet P1.2 but not on sheet P2.0. [Original comment: Revise the size of the existing natural gas main serving the water heater and the cook line; it is called out as 1-1/2" serving 647 CFH at 85 feet.]

Final Status

Task End Date Reviewer's Name Type of Review Description
08/02/2011 GERARDO BONILLA OUT TO CUSTOMER Completed
08/02/2011 SUE REEVES REJECT SHELF Completed