Permit Number: T11CM01613
Parcel: 14041063B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11CM01613
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/14/2011 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied 1. PREVIOUS COMMENT 8: THE SOILS REPORT USED IN THE DESIGN WAS NOT PROVIDED FOR REVIEW.
07/14/2011 GERRY KOZIOL WWM REVIEW Denied need pcrwrd 3rd fl capcityreview & approval - Michael Harrington - 740-6305
07/27/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
07/28/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. The structural detail (50/S1.5) states that the platform is for a maximum load of 250 pounds but the specified water heater along with the expansion tank results in a load of 401 pounds. Verify that the structural design is adequate for the new load. [Original comment: Provide a design for the mounting shelf for the water heater (WH-2) along with structural calculations to show that the water heater is safely supported. Reference: Section 301.2 IPC 2006.]
2. Comment not resolved. The specified 12"w x 8" h scuppers are adequate for each roof area covered by key note 7.4 and detail 5/A2 but the scupper/collector box assemblies covered by key note 7.9 and detail 6/A2 do not have sufficient dimensions for evaluation. Provide the scupper width, the downspout dimensions, and the size of the overflow cutout. In addition, provide calculations to show that the overflow cutout on the collector box is capable of handling the same flow as the required scupper. [Original comment: Provide roof drainage calculations for each scupper installation and provide additional calculations to show that the overflow cutout on the collector box is capable of handling the same flow as the required scupper. Reference: Sections 1101.7, 1106.1, 1106.2, 1106.4, 1106.5, 1107.1, and1107.3, IPC 2006.]
08/01/2011 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/04/2011 DELMA ROBEY OUT TO CUSTOMER Completed
08/04/2011 SUE REEVES REJECT SHELF Completed