Permit Review Detail
Review Status: Active
Review Details: SITE
Permit Number - T11CM01301
Review Name: SITE
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2011 | Any | LANDSCAPE | REVIEW | Active | |
| 05/04/2011 | ANY | NPPO | REVIEW | Active | |
| 05/04/2011 | JASON GREEN | ENGINEERING | REVIEW | Active | |
| 05/05/2011 | DAVE MANN | FIRE | REVIEW | Denied | Fire Comments: 1. Stairs and railings were installed without permits. Show complete compliance with IFC Chapter 10. 2. The occupancy has an A2 componant added. Show new occupant load calculations. Occpant load is shown as both 29.4 and 59.4. An A2 occupancy would likely require the extension of the sprinklers from the basement. If this is an F2 a fire separation will be required to the M occupancy next door. Provide new area calculations for the new occupancies. The information on this sheet shows an increase for sprinklers. This is only allowable if the building is fully sprinklered. |
| 05/05/2011 | TERRY STEVENS | ZONING | REVIEW | Denied | Client has decided to submit through the IID Core Overlay which requires a Development Plan or with a letter from the Zoning Administrator applying through the 10835 process. |
| 05/09/2011 | RBROWN1 | ADA | REVIEW | Passed | |
| 05/12/2011 | RONALD BROWN | H/C SITE | REVIEW | Denied | 1. Please provide an accessible route from 7th Av. Reference Zoning comments. 2. Please provide two accessible parking spaces in the parking lot complete with signage and accessible parking aisle. a. Please provide a large scale detail showing all dimensions, "Van accessible" parking space, slopes, signage, access to accessible route, aisle, and accessible symbols. 3. Provide an accessible route from the new accessible parking spaces to the building accessible route. Reference zoning comments for material of accessible route to building. 4. Please provide a large scale detail of all existing ramps showing all dimensions, height elevations, handrails, slopes and landings. a. Any ramp with slopes greater than 5% requires handrails. 5. Provide guardrails at the covered porch parallel to Toole Avenue. END OF REVIEW |
| 10/04/2011 | LEERAY HANLY | PLUMBING-COMMERCIAL | REVIEW | Approved |