Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T11CM01170
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/22/2011 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 04/28/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 05/02/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 05/02/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide energy code compliance calculations for the building envelope (the correct climate zone is Pima County < 4,000 feet) and for the mechanical equipment. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the SHGC for the fenestration. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006. |
| 05/02/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide roof drainage calculations and plans for the building addition (i.e. show the total roof areas, including contributory areas, that are being drained by the proposed scupper). Reference: Section 1101.11, UPC 2006. 2. The "Typical Wall Section" detail on sheet A-3 refers to a "CDI rain spot"; please clarify this item. |
| 05/03/2011 | DAVID RIVERA | ZONING | REVIEW | Denied | Zoning cannot approve the building plans until the sit eplan is approved. The building footprint must match the building footprint on the site plan. Ensure that the dimensions match. |
| 05/04/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | GENERAL 1. On most all architectural and structural drawings, the depiction of the existing conditions and building is way too light and illegible. Please correct the line weight as per the mechanical and electrical drawings and resubmit. 2. Please provide 2 copies of the structural calculations. Only one set was submitted with this package. 3. There are two different sheets enumerated as "A-1". Please reconcile. SHEET C1 4. An effect of this addition is that it increases the occupancy load and size of the office space for which you're Certificate of Occupancy was issued. A new Certificate of Occupancy will need to be issued with all the new addition information included. Please provide the following information and additional detailing: a. A new occupancy load including the new addition, existing first floor and existing second floor breakdown and summary. b. Please provide a new EXIT plan including the new addition load and the second floor load. Please provide a second floor plan and its proposed exiting. c. Please recalculate the required number of plumbing fixtures based upon the new total occupant load; existing 1st floor load, addition load plus 2nd floor load. This includes w.c., urinals, lavs, drinking fountains and mop sinks. a. Please show all toilets located on the second level. 5. This is a two story building. Please correct the building data to reflect this fact. a. Please provide a breakdown of all square footages to show the second level b. Please provide an occupant load calculation breakdown showing the 2nd floor load. 6. Please correct the Applicable Codes accessible code to ICC (ANSI 117.1, 2003 Edition). SHEET A1 7. This sheet is not an approved site development plan and differs from the submitted site development plan in several areas of new and existing parking layout. Please provide an approved site development plan showing accurately the new addition, all concrete walkways and their slopes, landscaping and please clarify modifications and definition of and to the decorative wall. SHEET A1 8. Please remove the new room titles and numbers from the Demo Plan. 9. General roof plan note 1: The alternate methods of non-vented attic design are not applicable to commercial apartment projects. They were intended for residential use only. We apologize for any confusion caused as this reference was published on our web site. It is over 10 years old and is not longer relevant or applicable as changes in the code now address this situation. a. All attic venting for this project must comply with the requirements of the 2006 IBC, Section 1203. SHEET A2 10. As per the toilet details shown on sheet A-3, the new toilet room is identified as a Unisex Toilet. As per the 2006 IBC, Section 1109.2.1, Unisex Toilets are considered for mercantile and assembly occupancies only. If the existing toilet fixture count (including the second floor) meets the occupant load requirement, a unisex toilet might be approved in an appeal to the building official. 11. Clarify any modifications to decorative courtyard wall. 12. Please show all walkways and landscape area outside decorative wall and inside courtyard. SHEET A-3 11. Please provide a large scale toilet floor plan showing all accessible dimensions, clearances and accessories. 12. Generic, typical toilet elevations are not acceptable. Please provide elevations of the exact toilet design showing all accessible dimensions, accessories and finishes. a. Please provide wall finish as required by the 2006 IBC, Section 1210.2. 13. At the "General Toilet Room - Mounting Height Notes" delete all references to ADA and clarify the 2006 IBC Chapter 11 and ICC (ANSI 117.1, 2003 Edition) for accessibility code compliance. 14. At the TYP PARTITION detail, clarify the bracing to the structure above. SHEET S2.1 15. Detail 16 calls for typical stud wall framing while page 11 of the calculations call for 600S162-33@16" o.c.. Please reconcile. 16. Detail 17 calls for typical stud wall framing while page 11 of the calculations call for 362S162-33@16" o.k.. Please reconcile. SHEET S3.1 17. Detail 4 calls for 362S162-33 studs to be at 24" o.c. while the calculations on page 11 calls for studs at 16" o.c. Please reconcile. 18. The calculations do not address the TJI calculations for the roof framing. END OF REVIEW |
| 05/05/2011 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | DATE: May 5, 2011 SUBJECT: Marana Health Care Engineering Review ADDRESS: 4355 N Wyatt PROPERTY OWNER: TMC REVIEWER: Elizabeth Leibold, P.E. ACTIVITY NUMBER: T11CM01170 SUMMARY: The submittal was received and reviewed by Engineering Division. Engineering does not recommend approval of the project until the following comments are addressed. COMMENTS: 1) DS Sec. 10-02.2.3.1.4.C.1: Submit a drainage report showing water surface elevation for 100-yr event, flow rate, and adjacent 100-year floodplain limits and discussion regarding whether the existing structure to be improved is in or out of a jurisdictional floodplain. State FFE for the existing structure. Discussion: There is a drainageway to the west of this project with the potential to convey a jurisdictional floodplain. Any improvements to the structural building for this project may be considered a substantial improvement to an existing floodprone structure if the value of this new improvement is 50% or more than the value of the existing structure in present day value. If the project is determined to be a substantial improvement, and, if it is determined that the lowest floor elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for floodproofing will be required and shall conform to City of Tucson and FEMA floodplain development requirements. Cumulative values will be accounted for each building structure, so that tracking of the 50% status is current. Valuation of the improvements at minimum is required for this project. 2) Submit Floodplain Use Permit Application, an application/processing fee of $50.00 (submittal fee). Engineering study review fees of $150.00 may be imposed for the drainage report review. 3) Submit 2 copies of the cost of improvement in U.S. Dollars, type of assessment used for valuation, calculated percent improvement, market value of the existing structure, title of the improvement, description of improvement, provide 8-1/2" x 11" map locating improvement, provide permit activity number(s) for related permits for this project (T11CM01170). If you need a copy of the list of items to include or exclude from the list of cost of the improvements you my get the list from the Engineering Counter or contact me and I will email you a copy. If you have any questions, I can be reached at 837-4934/ elizabeth.leibold@tucsonaz.gov Elizabeth Leibold, PE Civil Engineer Engineering Division Planning & Development Services Dept |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/11/2011 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 05/11/2011 | SUE REEVES | REJECT SHELF | Completed |