Permit Number: T11CM01119
Parcel: 13317062A

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T11CM01119
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2011 DAVE MANN FIRE REVIEW Approved
06/15/2011 LAITH ALSHAMI ENGINEERING REVIEW Approved
06/16/2011 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
06/22/2011 DAVID RIVERA ZONING REVIEW Approved
06/27/2011 GERRY KOZIOL WWM REVIEW Approved
06/27/2011 RICK MYERS PLUMBING-COMMERCIAL REVIEW Denied 1. Item not resolved: comment number one from 05/09/11. Coordinate the proposed water heater support as shown in detail 8/S3.1 and in detail 1/P-401. Reference: Section 314.5 2006 UPC.
2. Provide a material schedule to include: DWV piping material, potable and non-potable water piping material. Type of piping insulation for hot and hot return piping, and pipe identification requirements.
3. Provide the method of sterilization to be used. Reference: Section 609.9 2006 UPC.
4. See detail 2/P-401; this activity is in the City of Tucson not in the Town of Surprise.
06/30/2011 ROBERT SHERRY WATER REVIEW Approved
06/30/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
07/07/2011 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/13/2011 GERARDO BONILLA OUT TO CUSTOMER Completed
07/13/2011 SUE REEVES REJECT SHELF Completed