Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T11CM01032
Parcel: 116162510

Address:
1001 N MAIN AV

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T11CM01032
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/08/2011 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
04/08/2011 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
04/08/2011 JASON GREEN ENGINEERING REVIEW Approved April 8, 2011
FLOODPLAIN USE PERMIT NO.: T11OT00662
ADDRESS: 1001 N Main Tucson, Arizona 85705
PROPERTY OWNER: City of Tucson Parks and Recreation Department
900 S Randolph Way Tucson, Arizona 85719

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the City of Tucson Flood Hazard Area delineation of the West University Wash, specifically described as:

A portion of Parcel 116-16-2510, MOUNTAIN VIEW LOTS 13 THRU 20 & PARTS OF ABANDONED STREETS & ALLEY BLK 1
For the purpose of site grading, installation of a playground equipment and pedestrian access paths as shown on the approved Site Plan (T11CM01032).

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 8 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the proposed disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the site grading and storm drain connection within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Site Plan set which are made part of this permit.
4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T11OT00662 FOR INFORMATION PLEASE CALL 791-5550."
5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
7) See the associated activity T11CM01032.
8) This permit is specific to the improvements for 1001 N Main Ave as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: City of Tucson Parks and Recreation: Howard Duitt
ADDRESS: 900 S Randolph Way Tucson, Arizona 85719
PHONE: 520-837-8040
CONTRACTOR: City of Tucson Parks and Recreation
ADDRESS: 900 S Randolph Way Tucson, Arizona 85719
PHONE: 520-837-8040

(EXPIRATION DATE) Month: _04 Day: 08 Year: 2011

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
04/08/2011 RBROWN1 FIRE REVIEW Passed SIDEWALKS ONLY FIRE REVIEW NOT REQUIRED
04/08/2011 MICHAEL ST. PAUL ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/07/2011 CPIERCE1 OUT TO CUSTOMER Completed