Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T11CM01012
Parcel: 116193700

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11CM01012
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/10/2011 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
05/23/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Verify the submitted rim elevation for the next upstream sanitary manhole and the first floor elevation. As stated, the first floor of the building would be about 15.2 feet below the rim of the next upstream manhole. [Revise the site plan to show the size and route of the building water supply along with the location and size of both the water meter and the reduced pressure backflow preventer assembly. Reference: Section 103.2.3, UPC 2006.]
05/23/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Comment not resolved; specify the minimum resistance (R-value) for the new duct insulation, rigid and flexible. [Specify the minimum resistance (R-value) of the duct insulation to be used on this project. The minimum insulation for ducts located in indirectly conditioned spaces within the building envelope is R-4.2 (installed). Reference: Section 503.2.7, IECC 2006, as amended by the City of Tucson.]
2. Comment not addressed. Provide information on the sequence of operation for the restroom exhaust fan to show that all of the air supplied to the restrooms will be exhausted (i.e. the exhaust fan will be running whenever air is being supplied to the restrooms). Reference: Section 403.2.1 (4), IMC 2006.
05/23/2011 ROBERT SHERRY WATER REVIEW Denied Comment not resolved. Revise the site plan to show the route of the building water supply along with the location of both the water meter and the reduced pressure backflow preventer assembly. Reference: Section 103.2.3, UPC 2006.