Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Permit Number - T11CM01005
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/04/2012 | GERRY KOZIOL | WWM | REVIEW | Passed | |
| 09/05/2012 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 09/06/2012 | TERRY STEVENS | NPPO | REVIEW | Passed | |
| 09/10/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 09/17/2012 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | T11CM01005 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. SITE PLAN: 1. Clarify the building size, R106.1.1. The site plan shows a 40' x 60' building, but the plans show a 50' x 60' building. The 10' open ended structure must be located on the site plan, or revise the plans for a 40' x 60' building. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |