Permit Number: T11CM00979
Parcel: 11304001W

Address:
1220 E PRINCE RD

Review Status: Completed

Review Details: RESUB - SITE/GRADING ALL

Permit Number - T11CM00979
Review Name: RESUB - SITE/GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2012 RONALD BROWN H/C SITE REVIEW Approved
06/18/2012 MARTIN BROWN FIRE REVIEW Approved
06/22/2012 TERRY STEVENS ZONING REVIEW Passed DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: T11CM00979
1220 E. Prince Rd.
Site Plan

TRANSMITTAL DATE: 06/26/12

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. DS 2-02.2.1.A.6 Provide documentation that indicates the existing garage has been permitted as a garage/ storage. If not, then indicate the structure as proposed and building permits will be required. Provide dimensions and building height on the footprint of the structure.

2. DS 2-02.2.1.A.7 Provide the building setback from property lines for the garage. Provide building setbacks from the back of future curb (required 21' or the height of the structure back of future curb). See later comment regarding future curb location..

3. DS 2-01.2.1.A.8 The number of required parking spaces is based on the gross floor area of all structures including the garage. Therefore 82 parking spaces are required. A board of adjustment variance will be required or a parking study completed. Contact Glen Moyer for criteria regarding a parking study.

The 2 parking spaces indicated in the garage does not appear to be correct. Per the aerial photos it appears the garage has only a single bay door allowing for one parking space only. Revise.

4. DS 2-02.2.1.A.10 Provide both future and existing sight visibility triangles.

5. DS 2-01.2.1.A.11 The backup spur located north of the eastern most parking spaces des not meet the criteria of DS 3-05.2.2.D. 6" curb, 3' radius, and 3' clearance behind the curb.

At the northeast corner of the property provide a barrier to prevent vehicles from entering on to the property from the adjacent property.

Provide the minimum two way PAAL width dimension behind the northern most handicap parking spaces. (min. 24')

6. DS 2-02.2.1.A.12 The pedestrian circulation path connecting to the street north of the handicap parking spaces must be physically separated from the vehicular use area. Raised sidewalk. Revise.

7. DS 2-02.2.1.A.13 Clearly indicate the location of the existing pole sign along the east property line.

8. DS 2-02.2.1.A.19 The indicated existing sidewalk, curb, ramps, etc, along Prince Rd. are not located on the property but should be shown in the right of way.

Provide the location of the future curb with dimensions.

The future right of way is not shown correctly. The intersection widening and taper per the MS&R maps is a 75' half right of way 300' from the intersection tapering back 300' to a width of a 60' half right of way. Revise.

9. The indicated expansion calculations are not correct. Provide GFA expansion calculations ( existing 6601sq. ft., new garage 767 sq. ft., new dining patio 823 sq. ft., 1590 sq. ft. / 6601 sq. ft. = 24% expansion) No other expansion calculations are required.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\T11CM00979.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
07/03/2012 ANDREW CONNOR LANDSCAPE REVIEW Passed 1. A revised landscape plan was not included with this submittal.

2. The application will be reviewed for compliance when the revised documents are included in the submittal.

3. The following comments where not addressed from the previous review:

4. The proposed development in the front of the existing structure must meet the criteria for the MS&R future widening. Provide a future site & landscape plans showing how this site will meet code once the widening takes place along with a copy of the recorded MS&R covenant or design this project to meet the future widening requirements LUC 2.8.3.5.F

5. Clearly indicate on the site and landscape plans the location of existing pole sign along the east property line DS 2-02.2.1.A.13.

6. Provide both future and existing sight visibility triangles on the site and landscape plans DS 2-02.2.1.A.10

7. Ensure that all Zoning comments and concerns are addressed, and appropriate revisions are reflected on the landscape plan.

8. If necessary include with re-submittal approval documentation. Indicate on the lower right hand corner of the site plan, the variance case number, date of approval, and any conditions imposed.

9. Additional comments may apply.
07/06/2012 PAUL MACHADO ENGINEERING REVIEW Passed To: George Holguin DATE: July 11, 2012
8987 E. Tanque Verde Tucson, Arizona 85749

Subject: 1220 E. Prince Road, Guadalajara Grill
Site Plan, T11CM00979 (Third Review)
T13S, R14E, Section 30

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement

The Site Plan cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. It appears that the right-of-way information is not correct. Re-check the r/w and revise as required.
3. General Notes. The following general notes are required. Additional notes specific to each plan are required where applicable. D.S. 2-01.3.7.
6. List special exceptions, zoning variances, zoning and development standard modifications, overlay zones, and other reviews that are applicable to the project.
b. List overlay zones that are applicable to the property, such as Sec. 2.8.1, Hillside Development Zone (HDZ); Sec. 2.8.2, Scenic Corridor Zone (SCZ); Sec. 2.8.3, Major Streets and Routes (MS&R) Setback Zone; Sec. 2.8.4, Gateway Corridor Zone; Sec. 2.8.5, Airport Environs Zone (AEZ); Sec. 2.8.6, Environmental Resource Zone (ERZ); Sec. 2.8.7, Downtown Heritage Incentive Zone; Sec. 2.8.8, Historic Preservation Zone (HPZ), 2.8.9 Drachman School Overlay (DSO), or 2.8.10 Rio Nuevo And Downtown (RND) of the LUC; or Sec. 29-12 through 29-19 Watercourse Amenities, Safety, and Habitat (WASH) Ordinance of the Tucson Code, by case number, in lower right corner of each sheet. As a general note state that the project is designed to meet the overlay zone(s) criteria, and provide the case number, date of approval, what was approved, and conditions of approval. If there is more than one (1) lot within the site, the note should specify which lots are affected by the overlay zones. Projects involving Historic Preservation Zones, Downtown Heritage Incentive Zones (involving demolition), or overlay zones, require separate review and approval.
B. Drainage Notes. List the following notes as appropriate.
1. List the following notes on all plans/plats.
a. "The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall."
3. List the following note on all development package documents
a. "Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this (site or development) plan."
C. Streets and Roads Notes.
1. List the following note if applicable: "All new public roads within and adjacent to this project will be constructed in accordance with approved plans. Construction plans will be submitted to the City Engineer's Office for review and approval."
2. List the following note on all development package documents: "No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Development Standard 3-01.0."
D. Utilities Note. All development package documentss are to include the following note:
"Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public."
4. Existing Site Conditions. The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within fifty (50) feet of the site. On sites bounded by a street with a width of fifty (50) feet or greater, the existing conditions across the street will be provided. D.S. 2-01.3.8.
C. The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.
E. Indicate the ground elevation on the site based on City of Tucson Datum (indicate City of Tucson field book number and page).
5. Information on Proposed Development. The following information on the proposed project shall be shown on the drawing or added as notes. D.S. 2-01.3.9.
2. Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.
J. If street dedication is not required or proposed and the project site is adjacent to a Major Street or Route, draw the Major Street right-of-way lines for those streets. (Add the MS&R future sidewalk, right-of -way lines, sight visibility triangles, etc.)

Drainage Statement:
1. A Drainage Statement is a brief description of drainage conditions applicable for a site which are not affected by 100 year flows of 100 cfs, of more……per S.M.D.D.F.M., chap. II, 2.1.2. The DS must be submitted along with the site plan and accepted with the approval of the grading plan.
2. The content and format of the Drainage Statement should follow S.M.D.D.F.M., chap. II, 2.2.
3. Show the project address or administration address on the cover sheet of the DS.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/1220 E PRINCE RD_DP-SITE_PLAN_2-01.0
07/09/2012 GBONILL1 PLUMBING-COMMERCIAL REVIEW Passed Revise the site drawing to include the following information:
a. the location and size of the water meter
b. the location of the fire hydrants
c. the location of the gas meter (if one exists or is planned)
d. the location of the building connection to the public sewer
e. the location, invert, and rim elevation of the next upstream and downstream manholes
f. the first floor elevation for the building
Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006.