Permit Number: T11CM00977
Parcel: 116183320

Address:
450 N GRANDE AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T11CM00977
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/08/2011 DAVE MANN FIRE REVIEW Denied Fire Comments:

Onsite fire turn-around does not meet Development Standard for inside radius at handicapped parking.
04/08/2011 GBONILL1 ELECTRICAL-COMMERCIAL REVIEW Needs Review
04/08/2011 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET TS.1; PROVIDE INFORMATION AS TO OCCUPANCY TYPE AND FIRE PREVENTION SYSTEMS.
2. SHEET A.1: PROVIDE DRINKING FOUNTAIN AND SERVICE SINK ON DRAWINGS.
3. SHEET A.1: PROVIDE DETAIL FOR BRACING TOP OF INTERIOR PARTITION WALLS, INCLUDING BRACING SIZE AND SPACING, AND BRACING CONNECTION TO TOP OF PARTITION WALL AND TO EXISTING STRUCTURE ABOVE.
4. SHEET TS.1: PROVIDE PLUMBING COUNT PER CHAPTER 29 OF THE 2006 IBC AND INCLUDE ON DRAWING.
5. SHEET A.1; ELEVATION 2: DISTANCE TO PAPER DISPENSER SHOULD BE 7"-9" TO CENTERLINE OF DISPENSER PER ICC/ANSI A117.1-2003, FIGURE 604.7.
04/13/2011 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Everlasting Father Christian Church - Parking Reconfig.
T11CM00977
Building Plan (1st Review)

TRANSMITTAL DATE: April 13, 2011


1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning can not approve the building plan until the site plan has been approved.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t11cm00977.doc
04/14/2011 GERRY KOZIOL WWM REVIEW Approved
04/18/2011 PAUL MACHADO ENGINEERING REVIEW Approved
05/03/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Revise the plumbing plan (1/P.1) to remove the extra walls and fixtures shown in the background. Reference: Section 103.2.3, UPC 2006.
2. Provide the minimum plumbing facilities required by Table 2902.1 and Section 2902.2, IBC 2006, for A-3 (assembly) occupancy, i.e. service sink and drinking fountain.
3. Provide floor drains for the restrooms. Reference: Section 411.2, UPC 2006.
4. Show that the restroom floors slope toward the floor drains. Reference: Section 411.2, UPC 2006
5. Verify the required minimum water pressure required for the specified water closet is not greater than the 15-PSI used in the water pipe sizing calculations. Revise calculations as necessary. Reference: Section 608.1, UPC 2006.
6. The branch piping sizes called out for the urinal flush valve will result in a water velocity greater than 8 FPS. Limit the water velocity to less than 8 FPS for the copper piping. Reference: Sections 610.12 and A 6.1, UPC 2006 and IS 3-2003, Section 2.6.
05/03/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Provide calculations demonstrating adequate ventilation for the proposed occupancy of this building. Reference: Section 403.3, IMC 2006, as amended by the City of Tucson.
2. If air conditioning is supplied to the restrooms, verify that the sequence of operation for the restroom exhaust fans will exhaust all of the air supplied to the restrooms. Reference: Section 403.2.1 (4), IMC 2006.
05/03/2011 ROBERT SHERRY WATER REVIEW Denied 1. Revise the site drawing to show the location and size of both the water meter and the reduced pressure backflow preventer assembly. Reference: Section 103.2.3, UPC 2006.
2. Provide a letter from Tucson Water confirming that the use of a 5/8" water meter will be allowed for this project (there will be 22 fixture units in the building once the minimum plumbing fixtures are added to the plans which equates to a demand of 15 GPM). Note that this is an A-3 (assembly) occupancy.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/12/2011 DELMA ROBEY OUT TO CUSTOMER Completed