Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T11CM00850
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/11/2011 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | Ensure that all Engineering comments and concerns are addressed prior to NPP approval stamp. |
| 07/12/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | July 13, 2011 FLOODPLAIN USE PERMIT # T11OT01354 PROJECT ADDRESS: 831 W Calle Sur APPLICANT'S NAME: Pacua Yaqui Tribe Attn: Raul Sereno PROPERTY OWNER: Dolores Bravo The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the mapped regulatory floodplain as shown on the submitted Drainage Statement (Arrowhead Engineering, Inc, 07JUL11), specifically described as: Parcel 115-15-415A; Adelanto Lots 6& 7 BLK 2 For the purpose of constructing a new single family residence (SFR) in a mapped 100-year floodplain. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the owner. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 10 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application, approved Drainage Statement (Arrowhead Engineering, Inc, 07JUL11), and the engineered site plan prepared for this project. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) The proposed SFR is located within a mapped 100-year floodplain, therefore it is required to place the lowest finished floor elevation 1-foot above the calculated Base Flood Elevation as shown on the engineered site plan, stamped and dated by Merwin Yellowhair, P.E., dated 07JUL11 submitted for review. 4) For purposes of this permit the following flood elevations shall be used: Base Flood Elevation (BFE) = 2336.34 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2337.34 feet NAVD 1988 The lowest finish floor elevation and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 5) Floodplain Approval of elevation certificates, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the single-family residence as well as the identity and location of all other equipment/machinery servicing the single-family residence. 6) All work shall conform to the approved details and engineered site plan, which are made part of this permit. 7) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T11OT01354 FOR INFORMATION PLEASE CALL 791-5550." 8) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 9) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 10) See the associated activity T11CM00850. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson Planning & Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 07 Day: 13 Year: 2012 APPLICANT: Pacua Yaqui Tribe Attn: Raul Sereno ADDRESS: 4720 W Calle Tetakusim PHONE: (520) 879-5905 OWNER: Dolores Bravo ADDRESS: 831 W Calle Sur Tucson, Arizona 85705 PHONE: (520) 879-5905 (Applicants #) SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 07/14/2011 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 07/15/2011 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/19/2011 | SUE REEVES | OUT TO CUSTOMER | Completed |