Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T11CM00828
Parcel: 117170110

Address:
135 S 6TH AV #A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11CM00828
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/10/2011 JASON GREEN ENGINEERING REVIEW Denied DATE: May 11, 2011
SUBJECT: 135 S 6th Ave- 2nd Site Plan Engineering Review
TO: Metro Permit Inc., Attn: Lisa Bower
LOCATION: T14S R13E Sec13 Ward 6
REVIEWERS: Jason Green, CFM
ACTIVITY: T11CM00828 (Site Plan)


SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the Site Plan (T11CM00828) for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed:


SITE PLAN COMMENTS:

1) Completed.

2) Completed.

3) Completed.

4) Restated: DS Sec.2-02.2.1.A.6: Clarify the Real Estate Condition on Sheet s1. Per condition #1 and the TRE statement an 8-foot pedestrian access is required, however per the comment letter and dimensions shown on the plan only a 5-foot sidewalk is proposed with approval from TDOT. Clarify which dimension should be used or revise the condition on Sheet s1 to read per TDOT requirements. Both TDOT and Real Estate conditions must correspond with each other.

5) Restated: DS Sec.2-02.2.1.A.8: Clearly label the existing patio on the north side of the building as to be demolished (not abandoned). If the area is not to be used then it needs to be removed completely from the site, this will include all gates, railing and any proposed future outside storage. If this area is to be used then it needs to be shown n the Zoning calculations on Sheet a1.0. Per Sheet s1 the area is labeled only as to "abandoned."

6) Completed.

7) Restated: DS Sec.2-02.2.1.A.12: Revise the civil sheets to correctly label the dimension for the revised bike lane as 4.5-feet as per the site plan sheets. Currently the civil sheets label it as 4.4-feet which does not technically match the site plan dimensions.

8) Acknowledged.

9) Completed.

10) Completed.

11) Completed.

12) Restated: Approval from TDOT Permits and Codes for all improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to any construction within the public right-of-way. Contact Thad Harvison, (520)-791-5100 or Thad.Harvison@tucsonaz.gov for all right-of-way requirements and permit applications.


NEW COMMENTS: Additional comments have been generated based on the 2nd submittal and changes and or discrepancies to the plan set. It is recommended that a quality control check be preformed on the plan set prior to resubmittal.

1) Clarify Sheet s1.1 within the plan set and how it relates to the proposed site plan. Per Sheet s1.1 the parking layout differs from what is shown on site and what is shown on the last approved site plan stamped in 2001. Remove the sheet if not needed or clarify the use.

2) Clarify the Sheet Index as shown on Sheet a1.0. The sheets within the plan set should be in the same chronological order as shown in the index. Also clarify why the civil sheet 1 of 1 is not included within the index count.

3) Clarify the purpose of both civil sheets 1 of 1 and c1. Sheet c1 appears to include all information required for PDSD and TDOT approval. The only differences in the sheets that can be determined are that sheet 1 of 1 does not include the layout of the proposed patio within the right-of-way. If Sheet 1 of 1 is needed for TDOT approval then the sheet must match sheet c1 in dimensions, proposed improvements and all other aspects of construction.

4) Clarify TDOT condition #1 on Sheet s1. Per the condition it states TDOT would prefer a rail system rather than an opaque wall however the comment letter states that Thom Trivener, TDOT will accept an opaque wall if below 30-inches. Clarify which condition is acceptable and revise the condition on the plan set to match.


GENERAL COMMENTS:

Please provide a revised site plan that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Enclose "redlines" with the resubmittal package.

A meeting is requested to discuss this project with the consultant to help expedite the 3rd resubmittal prior to resubmitting the plans. I can be reached at 837-4929 to schedule a meeting.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
05/12/2011 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Janos Downtown
T11CM00828
Building Plan (2nd Review)

TRANSMITTAL DATE: May 12, 2011


1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning can not approve the building plan until the site plan has been approved.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t11cm00828.doc