Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T11CM00659
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/04/2011 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 03/04/2011 | RBROWN1 | ADA | REVIEW | Passed | |
| 03/07/2011 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Daniel J. Marks DATE: March 11, 2011 2643 4th Ave San Diego, CA., 92103 Subject: Taco Bell, 708 W. Ajo Way Site plan T11CM00659 (First Review) T14S, R13E, Section 26 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. It appears that the site plan is not depicting the actual site conditions. Although the revisions are considered minor for engineering, a correctly drawn site shall be included in the submittal. The following items are listed from the City of Tucson Development Standards and shall be shown on the site plan. 3. 2-02.2.0 - SITE PLAN CONTENT AND SPECIFICATIONS: 2.1 Site Plan. A. The site plan is drawn at a standard engineering scale no larger than l" = 60' on a sheet(s) no larger than 30" by 42" (24" by 36" recommended) and includes, but is not limited to, the following: 1. North arrow and scale. 2. Property description. 3. Project address. 4. Location map. 5. Lot dimensions and bearings. 6. All existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use. 10. Existing and future sight visibility triangles. 11. Points of egress and ingress including locations and width of driveways and parking area access lanes (PAALs). 18. Street names. 19. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. 21. Dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines. 29. Site plan number (T11CM00659). If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson - Planning and Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/708 W. Ajo Wy Site |
| 03/14/2011 | RONALD BROWN | H/C SITE | REVIEW | Denied | 1. This project is governed by the 2006 IBC which has as the ICC (ANSI 117.1 2003 Edition) as the compliant accessibility code. a. Please change all details and references from ADA to ICC (ANSI 117.1, 2003 Edition). b. Please review all accessibility design details and change them to be in compliance with the ICC (ANSI 117.1, 2003 Edition). c. An accessible compliant review for ADA Accessible Standards may be conducted upon an approved appeal to the building official, Mr. Ron Boose. If so desired, please complete a building official appeal and submit for review and approval. A fee of $132.00 is required for processing. 2. Generic details are not acceptable. Sheet nos. ADA1.0 and ADA 1.1 are mostly code copied details that that no relevance to the actual design of the accessibility elements of this project. Please delete all details not relevant to this project. a. Please provide large scale details of the accessible parking shown on sheet C2.0 and provide all accessible dimensions, slopes, signage, markings, symbols, ramps and access to the accessible routes in compliance with the ICC (ANSI 117.1 2003 Edition). c. Please note that detectable warning strips are not required for accessible parking aisles unless they are a part of a marked crossing. Please delete detectable warning strips shown at the aisle ramp. 3. Please provide only one detail of the accessible parking design layout with all the accessible requiremnts included on this one partial plan. Three plan details of the parking layout are not necessary. END OF REVIEW |
| 03/22/2011 | ANDREW CONNOR | LANDSCAPE | REVIEW | Passed | |
| 03/23/2011 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 03/23/2011 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 03/24/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the following information: a. the location and size of the water meter b. the location of the main water lines and fire hydrants c. the location of the gas meter (if one exists or is planned) d. the location and size of the public sanitary sewer e. the location of the building connection to the public sewer f. the location, invert, and rim elevation of the upstream and downstream manholes or cleanouts g. the first floor elevation for the building Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/23/2011 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 06/23/2011 | SUE REEVES | REJECT SHELF | Completed |