Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T11CM00658
Parcel: 130144450

Address:
3930 E 22ND ST

Review Status: Completed

Review Details: SITE

Permit Number - T11CM00658
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/04/2011 MARTIN BROWN FIRE REVIEW Approved
03/09/2011 RONALD BROWN H/C SITE REVIEW Denied 1. This project is governed by the 2006 IBC which has as the ICC (ANSI 117.1 2003 Edition) as the compliant accessibility code.
a. Please change all details and references from ADA to ICC (ANSI 117.1, 2003 Edition).
b. Please review all accessibility design details and change them to be in compliance with the ICC (ANSI 117.1, 2003 Edition).
c. An accessible compliant review for ADA Accessible Standards may be conducted upon an approved appeal to the building official, Mr. Ron Boose. If so desired, please complete a building official appeal and submit for review and approval. A fee of $132.00 is required for processing.
2. Generic details are not acceptable. Sheet nos. ADA1.0 and ADA 1.1 are mostly code copied details that that no relevance to the actual design of the accessibility elements of this project. Please delete all details not relevant to this project.
a. Please provide large scale details of the accessible parking shown on sheet C2.0 and provide all accessible dimensions, slopes, signage, markings, symbols, ramps and access to the accessible routes in compliance with the ICC (ANSI 117.1 2003 Edition).
b. Please provide only one partial detail plan with all the accessible requirements shown. Three plan details are not necessary.
c. Please relocate the accessible signage just inside the curb/accessible route line as per COT DOT standards and not in the auto paving area.
3. The marked crossing and ramp leading to the 22nd Street right of way is incomplete. There are no detail references and there are no details on the two ADA detail sheets that are revelant to this design.
a. Please provide a large scale plan of the marked crossing and the ramp.
1. Provide all dimensions, slopes, handrails, detectable warning strips, curb ramps and all other required accessible compliances required by ICC (ANSI 117.1, 2003 Edition), Sections 406.12, 406.13, 405, 406 and 106.
END OF REVIEW
03/09/2011 JASON GREEN ENGINEERING REVIEW Approved
03/10/2011 STEVE SHIELDS ZONING REVIEW Approved
03/15/2011 ANDREW CONNOR NPPO REVIEW Approved
03/15/2011 ANDREW CONNOR LANDSCAPE REVIEW Denied All plant material used for landscaping shall be selected from the Drought Tolerant Plant http://www.azwater.gov/azdwr/WaterManagement/AMAs/documents/2007_Plant_List_apha_botanical.pdf. Pennisetum alopecuroides 'Hamlin' [Dwarf Fountain Grass] is not included on list and is on the Arizona Wildlands Invasive Plant List. All Arborvitae species are not included on the list. Revise sheet L1.0 to include appropriate plant materials.
03/23/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the following information:
a. the location and size of the water meter
b. the location of the main water lines and fire hydrants
c. the location of the gas meter (if one exists or is planned)
d. the location and size of the public sanitary sewer
e. the location of the building connection to the public sewer
f. the location, invert, and rim elevation of the upstream and downstream manholes or cleanouts
g. the first floor elevation for the building
Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/21/2011 SUE REEVES OUT TO CUSTOMER Completed
06/21/2011 SUE REEVES REJECT SHELF Completed